1.
External Ground Stud
To connect an external ground wire.
2.
Input Power Cord
To connect to Utility.
3.
Circuit breaker
Over current protection.
4.
Output receptacles
To connect the equipment.
5.
Power Switch
To turn the PDU On/Off.
6.
Surge LED (green)
The LED is illuminated when providing Surge
protection. The LED is off when the Surge
protection devices are damaged or if the
utility power is not present.
7.
Power On LED (green)
The LED is illuminated when the utility power
is present. The LED is off when the utility
power is not present.
Chapter Three: Installation and Operation
The packing condition and the external outlook of the PDU should be inspected
carefully before installation. Retain the packing material for future use.
3.1. Unpacking
1.
Take the PDU out of the box.
2. Remove the PDU from the plastic bag.
Use CAUTION
the plastic bag holding
the PDU is very slippery so be careful in unpacking and handling the PDU.
3. Standard Package includes:
a. PDU
b. Vertical Mount (0U), mounting hardware
c. User's
Manual
d. Warranty
Document
e. Platinum
Protection
Document (if applicable)
3.2. Selecting Installation Position
The Minuteman PDU Series is intended to be install in a temperature controlled
environment that is free of conductive contaminants. Avoid locations near heating
devices, water or excessive humidity, or where the PDU is exposed to direct sunlight.
Route power cords so they cannot be walked on or damaged.
Operating Temperature (Max): 0 to 40 degrees C (+32 to +104 degrees F)
Operating Elevation: 0 to 3,000m (0 to +10,000 ft)
Operating and Storage Relative Humidity: 0 - 90%, non-condensing
Storage Temperature: 0 to 65 degrees C (+32 to +149 degrees F)
Storage Elevation: 0 to 15,000m (0 to +50,000 ft)
Rack Mount Instructions
- The following or similar rackmount instructions are
included with the installation instructions:
a. Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the rack environment may be greater than
room ambient. Therefore, consideration should be given to installing the
equipment in an environment compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
b. Reduced Air Flow - Installation of the equipment in a rack should be such that
the amount of airflow required for safe operation of the equipment is not
compromised.
5
c. Mechanical Loading - Mounting of the equipment in the rack should be such that
a hazardous condition is not achieved due to uneven mechanical loading.
d. Circuit Overloading - Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits
might have on over-current protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing
this concern.
e. Reliable Earthing - Reliable earthing of rack-mounted equipment should be
maintained. Particular attention should be given to supply connections other than
direct connections to the branch circuit (e.g. use of power strips).
3.3. Installation
3.3.1. Vertical Mounting 0 (zero) U
Side Mounting:
1. Snap on the 0U mounting brackets to the backside of the PDU as shown.
2. Orient the PDU to the desire position and then attach the PDU to the rack with
the retaining screws (provided) as shown.
3. The installation is complete. See Connecting the Equipment.
Side
Mount
Flush
Mount
Flush Mounting:
1. Align the center hole of the 0U mounting brackets (backside) to the mounting
hole on the rack. Attach the 0U mounting bracket to the rack with the retaining
screws (provided).
2. Snap the PDU into the 0U mounting bracket.
3. The installation is complete. See Connecting the Equipment.