24
PT SET
==================
POWER. ACT
SPEEDBYZ
MOUNT. MODE
IR M.SPEED
IR Z.SPEED
MIN.SPEED
SCAN. SPEED
BACK
/MENU
返回/MENU
POWER ACT: 0/1( the camera will move to no.0/1 preset position after 12 seconds
without control since power on), Off
SPEEDBYZ
:
only work for IR remote control:
On
(
when the camera zoom becomes larger, rotation speed comes down
)
, Off
MOUNT.MODE
:
UP, DOWN
IR M.SPEED
:
IR remote control move speed: 5~24
IR Z.SPEED
:
IR remote control zoom speed: 1~7
MIN.SPEED: Minimum start speed for serial command: 0~9
SCAN. SPEED: move speed: 4~15
5. RESET
Move the pointer to the (SET) in the Main Menu, click the
【
HOME
】
and enter the (SET) as
follow,
RESET
==============
SYS. RESET
CAM. RESET
PT. RESET
ALL. RESET
BACK
/
MENU
SYS. RESET
:
Protocol: VISCA; Address: 1; baud rate:9600;
R
S485:Off
CAM. RESET
:
camera parameter reset
PT. RESET
:
power action: Off; speed by zone: On; mount mode:Up;