15-14. Remove the Rack motor (M2)
4131D069AA
1. Open the right-side door.
2. Remove the top-front cover, top cover, rear cover,
left-side cover, controller protective cover, control-
ler box, high voltage unit, and the belt separation
solenoid. Use a permenant marker to scribe both
the plug and jack for easy reinstallation.
3. Remove the inside of the cam (1 E-clip) them
remove the rack drive assy. (5 screws)
4131D070AA
4. Disconnect the electrical connections to the rack
clutch, belt cleaner positioning sensor, and the
rack home position sensor.
5. Remove the rack clutch shaft them remove the
drive gear. (1 E-clip)
4131D071AA
6. Remove the rack motor. (2 screws)
C4131O065AA
Note:
Manually turn the misfeed clearing dial counterclock-
wise if the image transfer belt unit does not fully seat
after this procedure is completed. Sometimes the belt
cleaning separation cam can be out of place, thus
blocking full seating of the image transfer belt unit.