131
(4)
FATAL ERROR CODE 0CH: Malfunction of the power supply cooling fan motor
<Remedy>
(5)
FATAL ERROR CODE 0EH: Malfunction of the fusing cooling fan motor
<Remedy>
(6)
FATAL ERROR CODE 10H: Malfunction of the polygon motor
<Remedy>
Components for display of the warning
Power supply cooling fan motor (M4)
Master board (PWB-A)
Power unit (PU)
Controller control board (PWB-P)
Step
Remedy
Reference
page
WARNING DIAGRAM
Control signal
Location(electrical com-
ponent)
1
Check M4 operation.
T-3
M4_REM
3-D
2
Replace PU.
-
-
-
3
Replace PWB-A.
-
-
-
4
Replace PWB-P.
-
-
-
Components for display of the warning
Fusing cooling fan motor (M5)
Master board (PWB-A)
Power unit (PU)
Controller control board (PWB-P)
Step
Remedy
Reference
page
WARNING DIAGRAM
Control signal
Location(electrical com-
ponent)
1
Check M5 operation.
T-3
M5_REM
11-E
2
Replace PU.
-
-
-
3
Replace PWB-A.
-
-
-
4
Replace PWB-P.
-
-
-
Electrical components for detection of the malfunction
Print head unit
Master board (PWB-A)
Power unit (PU)
Controller control board (PWB-P)
Step
Remedy
Reference
page
WARNING DIAGRAM
Control signal
Location(electrical
component)
1
Replace the print head unit.
-
-
-
2
Replace PU.
-
-
-
3
Replace PWB-A.
-
-
-
4
Replace PWB-P.
-
-
-
Содержание magicolor 2300 Series
Страница 1: ...magicolor 2300 Series Service Manual 1750058 001A...
Страница 6: ...6...
Страница 7: ...7 SAFETY...
Страница 8: ......
Страница 23: ...23 GENERAL...
Страница 24: ......
Страница 32: ...32...
Страница 33: ...33 MECHANICAL ELECTRICAL...
Страница 34: ......
Страница 75: ...75 DISASSEMBLY ASSEMBLY 19971...
Страница 76: ......
Страница 106: ...106...
Страница 107: ...107 CONTROL PANEL SER VICE MODE DESCRIPTIONS...
Страница 108: ......
Страница 117: ...117 TROUBLESHOOT ING...
Страница 118: ......
Страница 128: ...128 3 Replace PWB A...
Страница 139: ...139 INDEX...
Страница 140: ......