1. Connect the output plug of the AC adapter to
the scanner’s DC terminal.
2. Plug the AC adapter into a standard household
outlet.
Securely plug the A connector of the USB cable into the scanner’s
USB port and the B connector into the computer’s USB port.
The scanner should be connected directly to the computer.
Attaching the scanner to a USB hub may prevent proper
operation.
9
8
S
CANNER SETUP
Before connecting the scanner to a computer, the DiMAGE Scan Utility must
first be installed. Read the software instruction manual for the installation
procedure.
The scanner should be placed on a level surface free from vibrations. It should be
located away from direct sunlight and in a clean, dry, well-ventilated area. Never
connect the scanner cable while data is being transferred between the computer and
peripheral devices.
Before connecting the scanner to a computer
Connecting the AC adapter
Connecting the USB cable
Turn on the scanner with the power switch. Start up
the computer.
When launching the DiMAGE Scan Utility, the
indicator lamp will blink when the scanner is
initializing. Once the indicator lamp glows steadily,
the scanner can be used.
When using an IEEE1394 interface with Windows
Me, always shut down the computer before turning
the scanner off. Otherwise a system error may result.
Turning on the scanner
Power switch
Indicator lamp
2
1
Connecting the IEEE 1394 (FireWire) cable
Securely plug the cable into the scanner’s and computer’s IEEE 1394
port. Either end of the cable can be connected to the IEEE 1394 port on
the scanner or computer.
The scanner should be connected directly to the computer. Attaching
the scanner to an IEEE hub may prevent proper operation.
When the scanner is initially connected to a computer with
a Windows 98, 98SE, or 2000 Professional operating
system, the found-new-hardware wizard will appear briefly.
No action is required. With Windows 2000, the “Digital
Signature Not Found…” message may appear. Click the
yes button to complete the scanner installation.
When the scanner is initially connected to a computer with a Windows XP operating
system, the found-new-hardware wizard will appear. Click the next button. The “not
passed Windows Logo testing” message appears. Click the continue-anyway button
to complete the scanner installation.
When the scanner is initially connected to a computer with a Windows 98, 98SE, or
2000 Professional operating system, the found-new-hardware wizard will appear
briefly. No action is required. With Windows 2000, the “Digital Signature Not Found…”
message may appear. Click the yes button to complete the scanner installation.
When the scanner is initially connected to a computer with a Windows XP operating
system, the found-new-hardware wizard will appear. Click the next button. The “not
passed Windows Logo testing” message appears. Click the continue-anyway button
to complete the scanner installation.