CALLING ROOM STATIONS 

 

To call other room stations: 

 

  Press and hold the ‘HOUSE’ button (4) at any room station 

(The green light (3) will turn on indicating your microphone is active) 

  Commence your conversation and release the ‘HOUSE’ button

 

to listen for a reply 

(The green light (3) will turn off at the station initiating the call and will turn on at all 

receiving stations as a signal for the person receiving the call to reply) 

- Those replying to a call need not press any buttons. All replies are ‘hands free’ 

  Continue the conversation by pressing the ‘HOUSE’ button

 

to talk and releasing the 

‘HOUSE’ button

 

to listen 

  When the conversation is complete the system will reset after approximately 15 

seconds from when the ‘HOUSE’ key was last released  

 

Note: 

Stations with volume controls set to minimum will not receive communication. 

 

 

 

 

 

CALLING DOOR STATIONS 

 

To talk to a visitor at the Front Door or Gate: 

 

  Press and hold the ‘DOOR’ button (5)

 

at any room station and commence the 

conversation (The green light (3) will turn on) 

  Release the ‘DOOR’ button to listen to reply 

- The visitor does not have to press anything.........just talk  

(The green light (3) will turn off) 

  Continue the conversation by pressing the ‘DOOR’ button to talk and releasing the 

‘DOOR’ button to listen 

  When the conversation is complete the system will reset after approximately  

15 seconds from when the ‘DOOR’ button was last released  

 

 

   

Содержание iCentral

Страница 1: ...Rev 2 MINICOM Intercom System Installation User s Manual...

Страница 2: ...o features and specifications at any time without prior notification in the interest of ongoing product development and improvement 2014 Ness Corporation ABN 28 069 984 372 iCentral Trade Dealer Enqui...

Страница 3: ...OR STATIONS 6 WIRING DIAGRAMS 7 CABLE TERMINATIONS 8 DOOR STATION ADJUSTMENTS 9 CHANGING THE CHIME 10 CHIME CH OUTPUT 11 LOCK LK OUTPUT 12 WIRING LOCK LK CHIME CH OUTPUTS 12 CABLE FUNCTIONS 14 CABLE C...

Страница 4: ...roblems due to excessive voltage drop The maximum number of Room and Door stations used in a system is generally limited to 4 in total CAUTION Failure to use specified cable may cause problems with th...

Страница 5: ...l boxes Stations installed on single brick walls will require wall boxes and the cable will need to be run in conduit and chased into the brick wall Where stations are required in bathrooms or laundri...

Страница 6: ...Star Wired from a central point or Loop Wired however the number of stations on a loop is governed by the length of the loop See section Maximum Length For Cable Runs Note Different cables have diffe...

Страница 7: ...gth of a cable run is taken from the station where the plug pack is connected CABLE RUN LENGTH V s NUMBER OF STATIONS ON RUN Distance Using 13 8V Supply Distance Using 12V Supply No of Stations On Run...

Страница 8: ...inals See diagram page 8 Screw metal chassis plate to back housing using 6 x small PT screws provided Fit optional plastic trim if applicable around protruding part of back housing Clip plastic front...

Страница 9: ...Y DOOR STRIKE RELAY INTERCOM CABLE FIGURE 8 CABLE STAR WIRED OR PLUG PACK DOOR STRIKE RELAY DOOR MECHANICAL CHIME RELAY STATION STATION STATION STATION ROOM ROOM ROOM INTERCOM CABLE FIGURE 8 CABLE LOO...

Страница 10: ...G CON COM1 COM2 BROWN BROWN WHITE ORANGE BLUE BLUE WHITE VR901 ROOM STATION 105 422 CAT5 Cable D70 DOOR STATION 105 819 VR2 E1 VR1 PROG SEL NOTE Plug pack can be wired into POS NEG at any station See...

Страница 11: ...ee diagram below Turning this pot will vary the speaker volume This adjustment is best made while someone is communicating to the door station from one of the internal stations Chime Volume The chime...

Страница 12: ...rocedure Press the Program button PROG The red LED illuminates and the current chime plays Press the Select button SEL The next chime option plays Repeatedly press the Select button until the desired...

Страница 13: ...e changed by means of the two programming switches SEL PROG situated on the door station circuit board as indicated below D70 DOOR STATION 105 819 VR2 E1 VR1 PROG SEL Procedure Press the Program butto...

Страница 14: ...UTS The Lock output LK and Chime voltage output CH will provide 12 Volt DC 50mA which can be used to power up relays which in turn will switch voltage to the device being used WARNING Using these outp...

Страница 15: ...LAY 12 V DC NEG LK DOOR STATION ELECTRIC STRIKE OPERATING AUTOMATIC GATES N C COM N O RELAY COIL RESISTANCE SHOULD NOT BE LESS THAN 240 OHM RELAY 12 V DC LK AUTOMATIC GATES DOOR STATION OPERATE LOCK O...

Страница 16: ...eting of calls etc Control voltage are present for duration of button press or chime activation COM1 COM2 COMMUNICATION LINES Carry balanced audio signals for Chime and communication CABLE COLOUR CROS...

Страница 17: ...Rev 2 MINICOM Intercom System User s Manual...

Страница 18: ...de Communication to and from all other room stations Communication to and from door stations Door Gate release optional Choice of 10 programmable door chimes Automatic reset circuitry so you do not ha...

Страница 19: ...iCENTRAL MINICOM USER MANUAL 17 PARTS IDENTIFICATION Door Gate Station Room Station 1 BELL PRESS BUTTON 4 MICROPHONE ACTIVE L E D 2 VOLUME CONTROL 5 DOOR CALL BUTTON 3 HOUSE CALL BUTTON...

Страница 20: ...releasing the HOUSE button to listen When the conversation is complete the system will reset after approximately 15 seconds from when the HOUSE key was last released Note Stations with volume control...

Страница 21: ...s set to minimum ACTIVATING LOCK OUTPUT Electronic door locks or Automatic gates where fitted can optionally be controlled from any room station To activate the Lock Output Press and release the HOUSE...

Страница 22: ...blems are experienced please check the applicable section in this manual Below are the most common problems and their solutions CHIME NOT SOUNDING AT ROOM STATION S Increase the Slide Volume Control s...

Страница 23: ...CIFICATIONS Control Microcontroller Microphones Electret Speakers Room Cloth surround 87mm 5W Door Mylar cone 65mm 1 5W Amplification Independent at each station Component technology Surface mount Pow...

Страница 24: ......

Отзывы: