![Minicom iCentral Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/minicom/icentral/icentral_installation-and-user-manual_1802004016.webp)
iCENTRAL MINICOM INSTALLATION MANUAL
14
CABLE FUNCTIONS
POS
12 to 13.8 VDC
NEG
0 VDC
CON
CONTROL - Carries different voltage levels generated by initiating station to
allow targeting of calls etc. Control voltage are present for duration of button
press or chime activation
COM1
COM2
COMMUNICATION LINES - Carry balanced audio signals for Chime
and communication.
CABLE COLOUR CROSS REFERENCE
CAT5 Cable
Telecom Cable
Valet Cable
POS
Brown
Red
Red
NEG
Brown / White
Black
Black
CON
Orange
Orange
Shielded Cores
COM1
Blue
Blue
Blue
COM2
Blue / White
White
White