![Minicom iCentral Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/minicom/icentral/icentral_installation-and-user-manual_1802004013.webp)
iCENTRAL MINICOM INSTALLATION MANUAL
11
CHIME (CH) OUTPUT
The “CH” Terminal provides an output voltage whenever the chime button is pressed.
The duration of this output voltage is set by 1of 4 programming options.
Chime Voltage Output Options
Option #1 Single flash - Voltage present for duration of Bell Press
Option #2 Double flash - Voltage present for duration of Chime
Option #3 Triple flash - Voltage present for 10 seconds from moment of Bell Press
Option #4 Quad flash - Voltage present for 30 seconds from moment of Bell Press
The chime output voltage duration can be changed by means of the two programming
switches (SEL & PROG) situated on the door station circuit board as indicated below.
D
70
D
O
O
R
S
TA
TIO
N
10
5-8
19
VR
2
E1
VR
1
PR
O
G
SE
L
Procedure
Press the Program button (PROG) – The red LED illuminates and the current chime is
played.
Press the Program button again to select the voltage output option mode
– The red
LED flashes the current output CH output option.
Press the Select button (SEL) – The next output option is displayed.
Repeatedly press the Select button until the desired CH output option is displayed.
Press the Program button again to lock in the selection and exit program mode – The
red LED extinguishes.
NOTE:
Pressing the Select button after all 4 output options have been sampled, will
return to the first output option.
Содержание iCentral
Страница 1: ...Rev 2 MINICOM Intercom System Installation User s Manual...
Страница 17: ...Rev 2 MINICOM Intercom System User s Manual...
Страница 24: ......