![MiNGARDi Micro One 230 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/mingardi/micro-one-230/micro-one-230_use-and-installation-manual_1801406011.webp)
GB
INSTRUCTIONS ON FITTING, USING AND
MAINTAINING THE ACTUATOR
Micro One
Installation for windows with an overlapped part
measuring 5 to 10 mm:
B01
Find and mark the centre line of the window and
movable wing.
B02
Remove the two side supports pointed out in grey
from the template for hopper-frame windows code
CD20303300 by bending them sideways.
Fit the top clamps code CD20302800 and bottom
clamps code CD20302900 on the template for
hopper-frame windows code CD20303300 and
lock them onto the template by screwing on the
two screws code A020300400-1 (M5x25 DIN
7984) without tightening them with force.
B03
Position this assembly on the window while
making sure that the template for hopper-frame
windows is all the way up against the frame and
that its two spyglasses (pointed out in grey) are in
contact with the wing; for horizontal positioning,
make the marked centre line coincide with the
indicator on the template (also see fig. A05).
Proceed with drilling by using the holes on the
bottom clamps as references; use those marked
by the symbol “*” on the figure. For aluminium
frame applications, drill with a 3.8-mm drill bit. The
fastening screws supplied are only for aluminium
frames. Contact the Mingardi S.r.l. technical
service for wooden, PVC or iron frames.
B04
B05
Use the two spyglasses on the template for
hopper-frame windows (shown in grey) for drilling
on the wing, which is necessary for fixing the
hopper-frame window bracket code CD20303400.
Use the same drill bit used for the previous
drilling.
Remove the two spyglasses (pointed out in grey)
from the template for hopper-frame windows using
the initiation shown in darker grey as the breaking
point.
B06
Loosen the two screws holding the clamps
together so as to be able to insert the Micro One
actuator from the front. Once inserted, screw on
the screws code A020300400-1 without tightening
them with force (see B02).
B07s
Fix the hopper-frame bracket to the wing using 2
screws code C094001600 (4.8x22 UNI 6954).
B08
Drill the third hole for fixing the hopper-frame
bracket and put in the third screw
C094001600
(4.8x22 UNI 6954).
B09
Loosen the two screws A020300400-1 and move
the Micro One actuator horizontally until the chain
head is centred in the hopper-frame bracket.
Afterwards, tighten the two clamp joining screws
with a 4Nm
±
10% torque.
Put on the elastic clip CD20303000.
-Connect the actuator to the electric system using
the enclosed diagrams and observing the safety
standards in force.
-Start the actuator to open the window, go to the
end of stroke and close again. This operation
tests that the actuator is working correctly, that the
limit switches trip and that the window is closing
properly.
Now secure the clamps to the frame using 4
screws code C094001600 (4.8x22 UNI 6954).
Содержание Micro One 230
Страница 1: ...Micro one 230V Micro one 24V ...
Страница 2: ...A01 A02 A03 A00 ...
Страница 3: ...A04c A04s A05 A06 A07 A08 A09 ...
Страница 4: ...B01 B02 B03 B00 ...
Страница 5: ...B04 B05 B06 B07c B07s B08 B09 ...
Страница 6: ...D01 D02 D03 A B C D A B E ...