INSTRUCTIONS ON FITTING, USING AND
MAINTAINING THE ACTUATOR
Micro One
A09
Lastly, put on the elastic clip CD20303000.
-Connect the actuator to the electric system using
the enclosed diagrams and observing the safety
standards in force.
-Start the actuator to open the window, go to the
end of stroke and close again. This operation
tests that the actuator is working correctly, that the
limit switches trip and that the window is closing
properly.
B
FITTING TO A HOPPER-FRAME
WINDOW
Installation for coplanar windows or windows
with an overlapped part that in any case does
not exceed 5 mm:
B01
Find and mark the centre line of the window and
movable wing.
B02
Fit the top clamps code CD20302800 and bottom
clamps code CD20302900 on the template for
hopper-frame windows code CD20303300 and
lock them onto the template by screwing on the
two screws code A020300400-1 (M5x25 DIN
7984) without tightening them with force.
B03
Position this assembly while making sure that the
template for hopper-frame windows is all the way
up against the frame and that its two side
supports (pointed out in light grey) are in contact
with the wing; for horizontal positioning, make the
centre line coincide with the indicator on the
template (also refer to fig. A05).
Proceed with drilling by using the holes on the
bottom clamps as references; use those marked
by the symbol “*” on the figure. For aluminium
frame applications, drill with a 3.8-mm drill bit. The
fastening screws supplied are only for aluminium
frames. Contact the Mingardi S.r.l. technical
service for wooden, PVC or iron frames.
B04
B05
Use the two spyglasses (pointed out in grey) on
the template for hopper-frame windows for drilling
on the wing, which is necessary for fixing the
hopper-frame bracket code CD20303400. Use the
same drill bit used for the previous drilling.
Remove the two spyglasses and the two side
supports from the template for hopper-frame
windows by bending them sideways.
B06
Loosen the two screws holding the clamps
together so as to be able to insert the Micro One
actuator from the front. Once inserted, tighten the
screws code A020300400-1 without using force
(see B02).
B07c
Fit the spacer for hopper-frame bracket code
CD20303500 onto the hopper-frame bracket and
fasten it all to the wing using 2 screws code
C094001600 (4.8x22 UNI 6954).
B08
Drill the third hole for fitting the hopper-frame
bracket and in the third screw C094001600
(4.8x22 UNI 6954).
B09
Loosen the two screws A020300400-1 and move
the Micro One actuator horizontally until the chain
head is centred in the hopper-frame bracket.
Afterwards, tighten the two clamp joining screws
with 4Nm
±
10% torque.
Lastly, put on the elastic clip CD20303000.
-Connect the actuator to the electric system using
the enclosed diagrams and observing the safety
standards in force.
-Start the actuator to open the window, go to the
end of stroke and close again. This operation
tests that the actuator is working correctly, that the
limit switches trip and that the window is closing
properly.
Now secure the clamps to the frame using 4
screws code C094001600 (4.8x22 UNI 6954).
Содержание Micro One 230
Страница 1: ...Micro one 230V Micro one 24V ...
Страница 2: ...A01 A02 A03 A00 ...
Страница 3: ...A04c A04s A05 A06 A07 A08 A09 ...
Страница 4: ...B01 B02 B03 B00 ...
Страница 5: ...B04 B05 B06 B07c B07s B08 B09 ...
Страница 6: ...D01 D02 D03 A B C D A B E ...