Slide out the locking bails on the six way ribbon connector and disconnect the cable six
way ribbon.
•
Slide the main PCB away from the battery assembly until the ends of the main PCB
disengage from the slots in the detector body near the battery compartment.
•
Gently tilt the top side (near the detector handle) of the main PCB away from the housing
and lift the main PCB from the detector body.
b.
The main PCB can now be replaced.
2
Figure 36: Lifting Main PCB Out of Detector
Figure 35: 10 Way Connector and Six Way Ribbon Cable
Cable
Six Way
Ribbon
10 way Connector