Minelab E-Trac Скачать руководство пользователя страница 7

Discrimination Menu 

The Discrimination Menu allows you to

 Select, Save, Edit and Combine

 Discrimination Patterns. 

Important

 

Note:

 ALL Discrimination Patterns Pre-Programmed into E-Trac are 

‘accepting’ 

Discrimination Patterns e.g. 

the Iron Disc Pattern accepts iron.  

E-Trac comes pre-loaded with ten (10) Discrimination Patterns which are:

- all metal – coins – Jewellery – foil – pull tabs – crown caps – screw caps – nails – iron – Fe Coins

NB:

 as E-Trac is a completely new innovative metal detector it allowed the engineers to go back to the 

drawing board and bring into line the complete conductive range of all metals in a 

linear fashion

: on the 

left are very low conductive, in the middle area mid conductive, and to the right, high conductivities with 
the most conductive i.e. copper and silver to the right hand side end of the linear scale.  The conductivity 
scale has a wider range of IDs (from 1 to 50) and the ferrous range is expanded also (1-35).  So on E-Trac, 
the Ferrous scale is on a vertical adjustment and the Non-Ferrous or Conductivity scale is on a horizontal 
adjustment.

This change is very important to owners of the previous FBS Explorer models as the axes were different 
i.e. ferrous was the horizontal scale and non ferrous was the vertical scale.  

But remember, E-Trac is a unique 

machine so you can expect new and distinctive features at every level!

Auto Latch (Semi-Automatic Discrimination Editing)

Within the Discrimination Menu, E-Trac has a brand new, very innovative feature called Auto Latch which 
provides semi-automatic editing of your Discrimination Pattern.  In this editing mode the Edit Frame will 
automatically move to the Ferrous (FE) and Conductive (CO) coordinates of the detected target.  You can 
then choose to accept or reject that target from your Discrimination Pattern using the Accept/Reject 
button found on E-Trac’s front panel.

The Combine Function

Again, this is a brand new feature which allows you to merge preset or 
saved Discrimination Patterns to create a new Discrimination Pattern.  
The Combine function should not be confused with how you select 
Discrimination Patterns via the ‘Select Menu’.

With Combine, you do not add or subtract whole Discrimination Patterns.  
The accepted target ‘white’ areas of a listed Discrimination Pattern are what 
you accept or reject from the Combine Discrimination Pattern. 
The two Smartfind™ Windows at the top of the Combine Screen are the Combine Pattern (left) and the 
active Disc Pattern (right).  The Active Pattern is the Discrimination Pattern currently being used in the 
Pattern / Digital Screen.

By default, the Combine Pattern (left Smartfind™ window) is empty.  As you scroll down the listed 
Discrimination patterns, areas of the Combine Pattern will flash relative to the white areas of the selected 
Disc Pattern.  For example, if you select the Jewellery Disc Pattern, then the white area of that pattern will 
flash in the Combine Pattern.  Each Pattern that is pre-programmed into E-Trac is, as I stated above, an 
accepting i.e. the Jewellery Disc Pattern accepts Jewellery, the iron disc accepts iron etc.  Therefore, the 
‘flashing’ area indicates where the object is located.

Содержание E-Trac

Страница 1: ...The evolution of discovery...

Страница 2: ...ks up its sleeve This detector is a new model the premiere flagship of the Minelab fleet and does not replace anything else instead it adds to the model line up and creates a new benchmark in software...

Страница 3: ...Main Menu QuickMask or Edit Screen pressing Detect returns you to the Pattern Digital Screen at any stage of operation QuickMask allows on the spot adjustments of the FE and CO rejection levels indepe...

Страница 4: ...h the software package and complete Xchange User Guide comes in the box and should be installed onto your PC Suggested alternate Patterns to get you up and running on Xchange can be downloaded from ww...

Страница 5: ...free movement to locate to the correct axis points of both ferrous and conductive scales as in 2 dimensional discrimination the principle behind Smartfind Main Menu allows you to browse through each...

Страница 6: ...for you to also create your own discrimination patterns giving a grand total of 10 personal patterns you can make up yourself for certain targets or to tackle difficult sites or perhaps to Xchange wit...

Страница 7: ...ovative feature called Auto Latch which provides semi automatic editing of your Discrimination Pattern In this editing mode the Edit Frame will automatically move to the Ferrous FE and Conductive CO c...

Страница 8: ...s For example if E Trac determines the Sensitivity Levels for each signal to be 20 15 and 10 the left hand bar and the numeric value of the Sensitivity gauge will display 20 The Suggested Sensitivity...

Страница 9: ...ption You can select 1 Tone where everything will have the same monotone sound including ferrous 2 Tone a low tone and a high one 4 Tone where the sound has 4 tones from low to high Multi Tone where E...

Страница 10: ...en and levels can be very different and where the areas being searched contain masses of iron targets Ground The Factory Preset is Difficult The Ground settings either Neutral or Difficult affects the...

Страница 11: ...the target response and the volume is proportional to the position of the target under the coil During use with Normal pinpoint say you have just detected a large sounding target it can at times be a...

Страница 12: ...ou had saved all your favourite settings on your PC via E Trac Xchange It would then be a simple matter of re loading them via the USB cable that comes with E Trac in the box Other New Features Liquid...

Страница 13: ...which took 2 years to develop this detector wheedled in and out of countless pieces of ferrous materials and for the first time working that site over 20 years allowed me to hear and recover several l...

Страница 14: ...he show although there can be no denying that the E Trac was designed with the Professional in mind this will also suit the first time buyer If an experienced detector fan you can choose to tune tweak...

Страница 15: ...Sensitivity Adjustment Fully Automatic adjustable to be more aggressive or conservative Manual Setting 1 30 Sensitivity Gauge Auto Level Manual Level Suggested Level Threshold Fine adjustment level f...

Отзывы: