Designation
Description
Abbr.
C3
C6
Unit
Nominal ambient-
temp. range
to hold the speciied performance
B
T
-10
+40
-10
+40
°C
Usableambient
temp. range
permissible for continuous operation
without damage
B
Tu
-30
+70
-30
+70
°C
Storagetemperature
range
without electrical and mechanical
stress
B
Ti
-40
+95
-40
+95
°C
permissible displacement from no-
minal load line at the head of the
load cell
E
max
≤10 t
S
ex
10
10
mm
Permissible eccentri-
city
E
max
>10 t
S
ex
5
5
mm
Vibration resistance Resistance against oscillations
(IEC 60068-2-6 Fc)
20 g, 100 h, 10
150 Hz
inluence of barometric pressure on
output
for E
max
= 2 t
PK
Smin
<200
<200
g/kPa
for E
max
= 5 t, 10 t
PK
Smin
<320
<320
g/kPa
Barometric pressure
inluence
for E
max
= 25 t, 50 t
PK
Smin
<420
<420
g/kPa
max. elastic deformation under ma-
ximum capacity
for E
max
≤25 t
S
nom
<0.5
<0.5
mm
Nominal delection
for E
max
= 50 t
S
nom
<0.8
<0.8
mm
Deinitions acc. to VDI/VDE 2637
The technical data given are intended solely as a product description and should not be
interpreted as guaranteed properties in the legal sense.
4 Speciications
Pendeo® Process-Digital Precision Compression Load Cell PR 6204
Minebea Intec
EN-13
Содержание Pendeo PR 6204 Series
Страница 31: ......