6 Connection
6.1 General information
NOTICE
The load cell cable end is protected against contamination and moisture by a
protective sheathing.
The protective sheathing should only be removed shortly before connecting!
-
Protect the cable ends against contamination. Moisture must not get into the open
end of the cable.
-
The digital load cell cable may be shortened.
-
The screen of the load cell cable is connected to the load cell housing. A PR 6024/68S
type cable junction box must be used.
-
Keep the load cell cables away from power cables.
-
The distance between measurement cables and power cables and/or components
under high voltage should be at least 1 m (reference value).
-
We recommend laying the load cell cables in separate cable trays or armored steel
pipes.
-
Power cables should be crossed at right angles while taking into account the
minimum distance of 1 m (reference value).
6.2 Load cell
Color Code
rd
=
red
gn
=
green
bu
=
blue
gy
=
gray
+ supply
+ supply voltage
- supply
– supply voltage
B signal
B signal
A signal
A signal
screen
Screen