Set this in Chapter
. Moreover, Supplementary batching, Nuzzle batching and
automatic free low compensation can be set if necessity requires.
11.6.1
Batching mode
The sequential batching mode is a mode to control the weighing sequence depending on
the increased amout of weighing value or the control time when the raw material is
batching in.
Judgment conditions
Status display
Judgment condition
ZERO BAND
?Gross weight (or Net weight) ?≤ Set value of ZERO BAND
When you set to [FIXED OPEN (Weight)]
Net weight ≥ Final (Setpoint) – Set weight
FULL FLOW
When you set to [FIXED OPEN (TIME)]
Passing from the time for start weighing to completion time
of coarse low
When you set to [FIXED OPEN (Weight)]
Net weight ≥ Final (Setpoint) – Set weight
MEDIUM FLOW
When you set to [FIXED OPEN (TIME)], [QUADRATIC EQUA-
TION] or [ARBITRARY]
Passing from the completion time for coarse low to comple-
tion time of middle low
DRIBBLE FLOW
Net weight ≥ Final (Setpoint) – Set weight
UNDER
Net weight < Final (Setpoint) – Under
OVER
Net weight > Final (Setpoint) + Over
OK
Final (Setpoint) – Under ≤ Net weight ≤ Final (Setpoint) +
Over
Operating explanation
-
When the start signal is input, Coarse low, Middle low and Fine low turns on.
Moreover, tare weight cancellation is provided with the input of start signal with the
setting at the same time.
-
The output of coarse low turns of when net weight becomes the value of [FINAL –
SET WEIGHT (FULL FLOW)] or the time of [Passing from the time for start weighing to
completion time of coarse low].
-
The output of middle low turns of when net weight becomes the valule of [FINAL –
SET WEGHT (MEDIUM FLOW)] or the time of [Passing from the completion time for
coarse low to completion time of middle low].
-
When the net weight becomes [Final (Setpoint) – Set weight (Fine low)], then the
output of Fine low turns of.
-
The comparative target of ZERO BAND (Empty) and the comparative target of
FULL value is selectable from [GROSS], [NET], [?GROSS?], [?NET?] or [OFF].
-
The near zero is simple comparison operation.
-
Coarse low, Middle low and Fine low will never become ON until the next start
signal will be input, once it turns of.
11 Weighing mode
Weight Controller CSD-918
Minebea Intec
EN-107
Содержание CSD-918 Series
Страница 239: ......