20
●
[
F-05
]
Display Refresh Time Selection
Select the proper display refresh time to reduce frequently
changing value.
Press or button at Function Setting Mode to display
[
F-05
] [
UPdR
].
Refresh Time
Set Value
Press
button
Flashing
alternately
Display Refresh Time Setting
Press or button to
select refresh time.
3 display refresh time
selections include:
200ms, 500ms,1000ms
UPdR
S00
500ms
1000ms
200ms
UPdR
UPdR
UPdR
S00
Flashing
alternately
Flashing
alternately
Flashing
alternately
1000
200
F-05
UPdR
Flashing
alternately
Flashing
alternately
Flashing
alternately
Flashing
alternately
Press
button to return to
Function Selection Mode
DIGITAL FLOW SENSOR
( INSTRUCTION MANUAL )
MF01
How to use
–
Operation setting instructions
●
[
F-06
]
Unit Selection
Select the flow unit of the sensor.
Press or button at Function Setting Mode to display
[
F-06
] [
Un1t
].
●
[
F-07
]
Flow Reference Standard Selection
Select the flow value is shown under standard or normal
condition.
Press or button at Function Setting Mode to display
[
F-07
] [
rEFE
].
●
[
F-08
]
Display rotation
Rotate the display vertically.
Press or button at Function Setting Mode to display
[
F-08
] [
rotA
].
Flow Sensor
Flow Reference
Display Rotation
Set Unit
Selected Condition
Set Value
Press
button
Press
button
Press
button
Flashing
alternately
Flashing
alternately
Flashing
alternately
Output Selection
Flow Reference Standard Selection
Display Rotation
Press or button to
select color display for
OUT1 or OUT2.
Press or button
to select the standard
or normal condition.
Press or button
to set display rotation.
LPM(L/min)
Standard
conditon (ANR)
Display rotation
"OFF"
CFM(ft
3
/min*10
-2
)
Normal condition
(NOR)
Display rotation
"ON"
Flashing
alternately
Flashing
alternately
Flashing
alternately
Flashing
alternately
Flashing
alternately
Flashing
alternately
F-06
F-07
F-08
Press
button to return to
Function Selection Mode
Press
button to return to
Function Selection Mode
Press
button to return to
Function Selection Mode
* NOTE: When the measured flow rate range is 500mL/min or
1000mL/min, the unit of LPM is selected to represent the unit in
mL/min.
NOTE
1. Stardard condition (ANR): the display value is calculated under 20°C, 1atm.
2. Normal condition (NOR): the display value is calculated under 0°C, 1atm.
3. Flow rate in the specification is the value at standard condition (ANR).
FLoy
rEFE
rotR
FLoy
rEFE
rotR
FLoy
rEFE
rotR
LPR
Anr
off
LPR
Anr
off
CPR
nor
on
Un1t
rEFE
rotR