87
4-11 PARAM_SEND
Description: the command performs two optional operations:
1) The scanner respond to a PARAM_REQUEST.
2)The host demand scanner to change particular parameter values.
Packet Format
Length
Opcode
Status
Option code
Data
type
Parameter
value
…
Checksum
0x23
(‘#’)
Field Descriptions
Table 4-13 Field Descriptions
Field Name
Format
Size
Description
Length
Length of message (not
including checksum).
1 Byte
Length Field
Opcode
0x23
1 Byte
Identifies this opcode type.
Status
Bit 0: Retransmit
Bit 5-1: Query property of
the parameter
Bit 6: Change Type
Bit 7: Command source
1 Byte
Bit0:Identifies the transmission status.
Bit5-1:Property of the parameter
0,Max value
1,Min value
2,Permanent value
3,Temporary value
4,Default value
5-15,Reserve
Bit6:1,Permanently change
0,Temporarily change
Bit7:
1, Host sends, requesting scanner change
parameter.
0, scanner sends, replying
PARAM_REQUEST command.
Option Code
ASCII value of the option
code
4 Bytes 4 bytes for each option code
Data type
0x48/0x44/0x53
1 Byte
ASCII value of character‘H’,’D’ or‘S’
‘H’: Parameter value is in hexadecimal type, 2
bytes.
‘D’: Parameter value is in decimal type, 2
bytes.
‘S’: Parameter value is in character string type,
Содержание ES4200
Страница 1: ...ES4200 Embedded Laser Barcode Scanner User Manual Version ES4200_UM_EN_V1 1 7...
Страница 2: ......
Страница 10: ...4 1 4 Decode zone Figure 1 2 High density series...
Страница 11: ...5 Figure 1 3 Long range series...
Страница 108: ...102 11 Configuration alphanumeric entry barcode To finish parameter setting please scan the bar code below...