8
Installation
Heat sinking
MM20000-series drives require an additional heat sink, p/n
223-0159, when the continuous armature current is above 5
ADC. Apply a thermally conductive heat sink compound (such
as Dow Corning® 340 Heat Sink Compound) between the
drive chassis and heat sink surface for optimum heat transfer.
Line fusing
Minarik drives require an external fuse for protection. Use fast
acting fuses rated for 250 VAC or higher. Table 1 lists the
recommended line fuse sizes.
Table 1. Replacement Line Fuse Sizes
90 VDC Motor
180 VDC
Max. DC Armature AC Line Fuse
Horsepower
Horsepower
Current (amps)
Size (amps)
1/20
1/10
0.5
1
1/15
1/8
0.8
1.5
1/8
1/4
1.5
3
1/6
1/3
1.7
3
1/4
1/2
2.6
5
1/3
3/4
3.5
8
1/2
1
5.0
10
3/4
1 1/2
7.6
15
1
2
10
15
Minarik Corporation offers two fuse kits: part number
050–0066 (1–5A Fuse Kit) and 050–0071 (5–15A Fuse Kit).
See Replacement Parts (page 41) for fuse kit contents.