Troubleshooting
Motor does not run
1. Check for blown fuses or tripped circuit breaker.
2. Verify that the speed adjust potentiometer is connected
correctly.
3. Verify that the speed adjust potentiometer is not set to its zero
position.
4. Verify that the inhibit pin connections are not shorted together
or closed.
5. Verify that the drive is receiving AC line voltage.
6. Check that the drive is not in current limit. The red current
limit LED must be off. If the red current limit LED is on,
verify that the motor is not jammed. It may be necessary to
increase the CURR LIMIT setting if it is set to a value lower
than the current rating of the motor (page 24).
Fuses or circuit breaker blows
1. Check all wiring for shorts, grounds, or misconnections.
2. Check that the drive is configured to match the motor rating.
3. Check that the motor is not jammed or restricted from
movement.
4. Check that the fuse size is correct for the motor being driven.
250-0277.qxd 6/9/00 1:00 PM Page 29