![Minarik C1MMXL05-D240AC Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/minarik/c1mmxl05-d240ac/c1mmxl05-d240ac_user-manual_1800560027.webp)
19
Calibration
Each drive is factory calibrated to its maximum horsepower
rating. Readjust the calibration trimpot settings to accommodate
lower horsepower motors.
All adjustments increase with CW rotation and decrease with
CCW rotation. Use a non-metallic screwdriver for calibration.
Each trimpot is identified on the printed circuit board.
Warning
Dangerous voltages exist on the drive when it is powered,
and up to 30 seconds after power is removed and the motor
stops. When possible, disconnect the voltage input from the
drive before adjusting the trimpots. If the trimpots must be
adjusted with power applied, use insulated tools and the
appropriate personal protection equipment. BE ALERT.
High voltages can cause serious or fatal injury.
250-0277.qxd 6/9/00 1:00 PM Page 19