Installation
Field output connections
The field output is for shunt wound motors only. Do not make
any connections to the field output when using a permanent
magnet motor. Table 2 shows where to connect the field leads of a
shunt wound motor.
Table 2. Field Output Connections
Line Voltage
Approximate Field
C1/C4MMXL
(VAC)
Voltage (VDC)
Connections
115
50
F1 and L1
115
100
F1 and F2
230
100
F1 and L1
230
200
F1 and F2
Use 16 AWG wire to connect the field output to a shunt wound
motor.
A fuse is connected to field output connection F2. The value of
this fuse must be a minimum of 250 volts and 150% of the rated
motor field current.