© 2014 MIMAKI ENGINEERING CO.,LTD.
7.6
P.10
7.6 Image Quality Adjustment
R.1.2
7. Check and compensate the patterns.
Input the adjustment value (the measured value:
μ
m) so that the
impact dots of other nozzle lines (7 lines) are at the same
position in the Y-direction, referring to the reference nozzle
H1A line.
Check and execute the compensation for H1A-H1B ~ H2D.
[
] / [
] : Compensating value input (Input unit: 20 µm)
[ENTER] : Confirms (Next)
8. When compensated, draw and check the patterns again.
Return adjustment
9. On the [SELECT] display, select “ReDir”, and adjust it in the
same way as “SiDir”.
[
] / [
] : Switches
[ENTER] : Confirms (Next)
10. Press the [ENTER] key to draw the pattern.
[ENTER] : To start Pattern drawing
[
] : To the compensation display
(Without drawing)
11. When compensated, draw and check the patterns again.
900Hi SiDir WF1
H1A-H1B : 0.0
-99.9~99.9
900Hi SiDir WF1
H1A-H1C : 0.0
-99.9~99.9
Magnify by a microscope, and
measure it in inside readings.
Input the compensating value, referring to the left
figure, if the displacement on the drop position of
head applied for the compensation occurs either right
or left against the reference head.
Repeat “Drawing -> Checking (Compensating)” until
any compensation is not required.
#PRINT ADJUST
SELECT:ReDir
#PRINT ADJUST
ReDir:PRINT
Pattern drawing
SiDir
BiDir
#PRINT ADJUST
SELECT :ReDir
900Hi ReDir WF1
H1A-H1B : 0.0
-99.9~99.9
900Hi ReDir WF1
H1A-H1C : 0.0
-99.9~99.9
Repeat “Drawing -> Checking (Compensating)” until
any compensation is not required.
INSTALLATION GUIDE > Outputting Plots > Image Quality Adjustment
Model
JV400-130/160LX
Issued 2011.02.15 Revised 2013.10.10 F/W ver.
2.50
Remark
1.2