- 3.8 -
6.
Open the station cover.
Use and push a cotton swab contained clean-
ing liquid (A29) to take off some dust on the
felt surface.
Use a cotton swab contained cleaning liquid
(A29) to take off some inks on the rubber sur-
face.
7.
Clean the wiper and press the [ENTER] key.
8.
Fill the cap with the cleaning liquid (A29) using
a syringe.
9.
Close the station cover, and press the [ENTER]
key.
Wiper Cleaning
Completed
: ent
Fill Up Washings
Completed
: ent
Felt surface
Rubber surface
Don’t rub.