— 1.24 —
Rendering the set values on the personal computer effective [MODE SET]
> [CMD SW]
The set values (commands) that are rendered effective are specified either those set on the opera-
tion panel or those set on the CAD.
Set values
VALID:
If items that are set on the operation panel of this device can also be set on the
CAD, the latest command specified is given priority. If the device receives data
set on the CAD after the data have been set on the operation panel, the data
received will be given priority.
INVALID: Commands that are set on the operation panel of the device are given priority
while ignoring commands set on the CAD.
1
Press the
PAGE
+
key several times
until the LCD indicates page 3 of the
LOCAL MENU.
2
Select the [MODE SET].
3
Press the
PAGE
+
key several times
until the LCD indicates page 3 of the
[MODE SET].
4
Set the [CMD SW] to one of the fol-
lowing.
VALID, INVALID
5
Enter the input values.
Press the
END
key to enter the input
values.
If you do not enter the input data, press
the
END
key.
[ LOCAL ]
1 / 4
TOOL SELECT
———>
CONDITION
———>
TEST CUT
———>
[ LOCAL ]
3 / 4
INTERFACE
———>
MODE SET
———>
SELF TEST
———>
< MODE SET >
1 / 6
Z STROKE
∗
7mm >
MULTI-PASS
——— >
RESERVE
< MODE SET >
3 / 6
ROTATE
∗
+90
°
>
COMMAND
——— >
CMD SW
∗
INVALID >
< MODE SET >
3 / 6
ROTATE
∗
+90
°
>
COMMAND
——— >
CMD SW
VALID >
END
[ LOCAL ]
3 / 4
INTERFACE
———>
MODE SET
———>
SELF TEST
———>
F3
+
F2
+
PAGE
+
PAGE
+
Содержание CF2 Series
Страница 26: ...1 10 Operation panel VACUUM POWER X Y PAGE C E E N D ORIGIN REMOTE LOCAL F1 F2 F3 1 2 3 4 9 8 6 5 7 10 11 12 13...
Страница 48: ...1 32...
Страница 120: ...3 24...
Страница 138: ...4 18...
Страница 176: ...A 12 C OUTPUT SAMPLES Cutting quality 1 Cutting quality 2...
Страница 177: ...A 13 ASCII dump list Sample coated...
Страница 178: ...A 14 Sample E corrugated Sample B corrugated...
Страница 179: ...A 15 Circle cutting R 3 5 10 20 50 100 Parameter dump list R 3 R 5 R 10 R 20 R 50 R 100...
Страница 185: ......
Страница 186: ...D201402 1 30 16062008 MIMAKI ENGINEERING CO LTD 2008 EM FW 2 50...