17
English
17
Battery cat no.
Cell type
DC
volts
Capacity
Cell no.
MXFCP203
Li-ion
72 V
≤
3.0 Ah
20
MXFXC406
Li-ion
72 V
≤
6.0 Ah
2 x 20
Do not recharge primary cells (non-rechargable).
Do not store the battery pack together with metal objects (short
circuit risk).
No metal parts must be allowed to enter the battery section of
the charger (short circuit risk).
Never break open battery packs and chargers, and store them
only in dry rooms. Keep the battery packs and chargers dry
at all times.
The battery clamps of the charger are fed by the mains supply.
Do not touch the tool with conducting objects.
Never charge a damaged battery pack; replace it with a new
one.
Before use, check the product, cable, and plug for any
damages or material fatigue. Repairs should only be carried
out by authorised service agents.
The product is not intended for use by persons (including
children) with limited physical, sensory, or mental capabilities
or have insu
ffi
cient experience or knowledge, unless they are
supervised by a person who is legally responsible for their
safety or have been instructed by them in the safe use of the
product. They should be supervised to ensure that they do not
play with the product. When the product is not in use, it should
be secured out of their reach.
ADDITIONAL SAFETY INSTRUCTIONS
Remove the battery pack before starting any work on the
product.
Do not dispose of used battery packs in the household refuse
or by burning them. MILWAUKEE distributors o
ff
er to retrieve
old batteries to protect our environment.
Do not store the battery pack together with metal objects (short
circuit risk).
Use only MXF System chargers for charging MXF System
battery packs. Do not use battery packs from other systems.
Battery acid may leak from damaged batteries under extreme
load or extreme temperatures. In case of contact with battery
acid, wash it o
ff
immediately with soap and water. In case
of eye contact, rinse thoroughly for at least 10 minutes and
immediately seek medical attention.
ADDITIONAL BATTERY SAFETY WARNINGS
WARNING!
To reduce the risk of
fi
re, personal injury, and
product damage due to a short circuit, never immerse the
product, battery pack, or charger in
fl
uid or allow
fl
uid to
fl
ow
inside them. Corrosive or conductive
fl
uids, such as seawater,
certain industrial chemicals, and bleach or bleach-containing
products, etc., can cause a short circuit.
SPECIFIED CONDITIONS OF USE
The product is intended to be used as a light source
independent from the mains supply.
The charger can charge speci
fi
ed MILWAUKEE battery packs.
Do not use the product for any other purpose.
FUEL GAUGE
When the product is turned on, the fuel gauge displays the
battery pack's remaining run time. The fuel gauge mirrors the
fuel gauge on the battery pack. When less than 10% of charge
is left, one light on the fuel gauge
fl
ashes 4 times. When the
battery reaches 0% charge, the fuel gauge
fl
ashes 8 times.
Charge the battery pack.
10-32%
32-55%
55-77%
77-100%
MAINS CONNECTION
Connect only to a single-phase AC current and only to the
system voltage indicated on the rating plate. It is also possible
to connect the sockets without an earthing contact as the
design conforms to Safety class II.
CHARGING TIME
Battery cat no.
Volts
Capacity
Approximate
charging time
MXFCP203
72 V
≤
3.0 Ah
45 min
MXFXC406
72 V
≤
6.0 Ah
90 min
LI-ION BATTERIES
The rechargeable batteries are partially charged. The LED on
the battery indicates the state of charge.
The rechargable battery switches to its non-operative state
when it is not used for a long period.
When fully discharged, the rechargeable battery automatically
turns o
ff
(depth discharge not possible).
Under extreme circumstances, the internal temperature of
the battery pack could become too high. If this happens, the
battery shuts down.
Place the battery pack on the charger to charge and reset it.
The state of charge can be read by pressing the button on the
rechargeable battery. The battery can be left in the product
while the reading is taken but it must be turned o
ff
at least one
minute beforehand (otherwise the display will be inaccurate).
The number of LEDs illuminated indicates the state of charge.
A
fl
ashing LED indicates a maximum power reserve of 10%.
As a general principle, if the product should fail to work after
inserting the rechargeable battery, then the battery should
be plugged into the charger. The displays on the battery and
charger then provides information about the condition of the
battery.
The output is reduced when working in low temperatures.
CHARACTERISTICS
After inserting the battery into the reception of the charger, the
battery automatically charges (red control lamp is illuminated
continuously).
When a hot or cold battery pack is inserted into the charger
(
fl
ashing red lamp), charging begins automatically once the
battery reaches the correct charging temperature (0°C...40°C).
The maximum charging current is
fl
owing when the temperature
of the li-ion battery is between 0°C and 30°C.
The battery’s charging time is between 45 minutes and 90
minutes, depending on the state of discharge.
Содержание MXF TL
Страница 2: ... 8 14 13 12 ON OFF 2 ...
Страница 3: ...4 6 15 10 3 ...
Страница 5: ...5 click 1 2 3 4 Click ᤃㆊ㚨 拍答声 䆨 คลิก Klik Tiếng tách クリック ...
Страница 7: ...7 1 3 2 click Click ᤃㆊ㚨 拍答声 䆨 คลิก Klik Tiếng tách クリック ...
Страница 8: ...8 max 3100 mm ...
Страница 10: ...10 1 2 3 ...
Страница 11: ...11 4 5 ...
Страница 14: ...14 77 100 55 77 32 55 10 32 10 8x 4x ...
Страница 15: ...15 ...
Страница 47: ......
Страница 48: ...01960070901Q 01A 58 14 9994d1 ...