background image

6

1. Turn the tool to

 ON and to 

Horizontal Leveling Accuracy 

It is also suggested to mount the Laser Level to a 

Tripod for easy adjustment. 

Securely mount the tool on one side of the room and 

centered between walls A and B. Direct the laser 

lines toward the other side of the room such that the 

horizontal line appears on both walls A and B. Allow 

the laser to Self-Level.

 Horizontal 

Level Line mode.

2.

A

B

10m

5m

3.

4. Adjust the height of the tool (using the tripod or

by adding shims, if required) such that the center

of the horizontal line is projected exactly against

the previously marked point II on wall B. Ensure

the Laser is self-leveled after alignment.

5. Mark the center of horizontal line on wall A (point

III). Take care that point III is aligned as vertical

as possible above or below point I.

6. The distance d between marked points I and III on 

wall A indicates the actual deviation (d) of the tool.

A

B

d

10m

5m

7.

A free measuring space of approximately

10m x 10m on a firm surface between two walls or 

structures A and B is required for the check.

At a distance of 5m from the laser, mark the 

centre of the horizontal line on Wall A 

(Point I). Do the same on Wall B (Point II).

Move the Laser 10m toward the opposite wall and 

rotate the laser 180°. Allow the laser to Self-Level.

Vertical Leveling Accuracy

2.

1. 

 Vertical Plumb 

Perpendicular 

3.

 Turn the tool to 

 ON and to 

Line & Plumb Points Mode or 

Level & Plumb Point  Mode.

 Position the tool with the laser towards the door 

opening. Allow the tool to self-level.

4.

2.5m

2.5m

2.05m

5. Move the laser level directly behind point II on the 

other side of the door. Align the vertical laser line

so the centre is directly aligned with points I and II. 

6. Mark the centre of the vertical line at the upper

edge of the door opening (point IV).

7. Measure the height of the door opening.

8. The distance between points III and IV on the

upper door opening is the vertical deviation (d)

of the tool.

Mark the centre of the vertical laser line on the 

floor in the middle of the door opening (point I), 

at a distance of 2.5m beyond the door opening 

(point II), and at the upper edge of the door 

opening (point III).

A door opening with approximately 2.5m of space on 

each side of the opening is required for this check.

Securely mount the tool 2.5m from one side of 

the door opening.

For the Measuring distance of 2 x 10m = 20m, the 

maximum allowable deviation (d) is: 20m x 

±3.18mm ÷ 10m = ±6.36mm Thus, the difference 

d between points I and III should not exceed 

6.36mm (max.) at 20m.

Содержание M12 CPL

Страница 1: ...OPERATOR S MANUAL Cat No M12 CPL M12 CROSS LINE PLUMB POINTS LASER WARNING To reduce the risk of injury user must read and understand operator s manual ...

Страница 2: ...er in fluid or allow a fluid to flow inside them Corrosive or conductive fluids such as seawater certain industrial chemicals and bleach or bleach containing products etc can cause a short circuit Do not charge non rechargeable batteries Do not dispose of tool or batteries with household waste material Tool and batteries that have reached the end of their life must be collected separately and retu...

Страница 3: ...pplied with your charger and battery Removing Inserting the Battery To remove the battery push in the release buttons and pull the battery pack away from the tool changing or removing accessories WARNING Always remove battery pack before To insert the battery slide the pack into the body of the tool Make sure it latches securely into place WARNING reco Only use mmended accessorie for thi s s tool ...

Страница 4: ...urns OFF the laser and locks the pen pendulum self leveling is disabled The to indicate that the projected lines are not level or plumb NOTICE The ON mode disables self leveling and therefore is not intended for projecting a level or plumb line and store the Laser Level in the protective carrying case Use the MODE button to cycle through the three laser modes Horizontal Level Line Vertical Plumb L...

Страница 5: ...ontact a MILWAUKEE service facility Failure to do so could result in rejection of warranty claim Securely mount the tool within 30cm of wall A as shown below 1 Ambient temperature gradients can impact laser accuracy For accurate and repeatable results the following procedure should be conducted with the laser elevated off the ground and placed in the centre of the working area Abusive treatment of...

Страница 6: ...oint I Do the same on Wall B Point II Move the Laser 10m toward the opposite wall and rotate the laser 180 Allow the laser to Self Level Vertical Leveling Accuracy 2 1 Vertical Plumb Perpendicular 3 Turn the tool to ON and to Line Plumb Points Mode or Level Plumb Point Mode Position the tool with the laser towards the door opening Allow the tool to self level 4 2 5m 2 5m 2 05m 5 Move the laser lev...

Страница 7: ...e of the plumb point on the floor point II tool since certain cleaning agents and solvents are harmful to plastics and other insulated parts Some of these include gasoline turpentine lacquer thin ner paint thinner chlorinated cleaning solvents ammonia and household detergents containing am around tools Cleaning the Lenses Carefully wipe the surface with a cotton swab moist ened with water Repairs ...

Страница 8: ...reet Penrose Auckland 1061 New Zealand DESIGNED BY MILWAUKEE ELECTRIC TOOL CORP PROFESSIONALLY MADE IN CHINA PRINTED IN CHINA MILWAUKEE prides itself in producing a premium quality product that is Nothing But Heavy DutyTM Your satisfaction with our products is very important to us If you encounter any problems with the operation of this tool please contact your authorised MILWAUKEE dealer For a li...