7
9.
2.
Plumb Dot Accuracy
Vertical Plumb
Level & Plumb
Turn the tool to
ON
and to
Line Mode or
Perpendicular
Point Mode.
3.
5m
4. Rotate the tool 180°. Align the centre point of the
5. Mark the centre of the top plumb point on the
reference line on the ceiling (point III).
d
6.
MAINTENANCE
WARNING
To reduce the risk of injury, always
WARNING
To reduce the risk of personal in-
remove the battery before perform-
ing any maintenance. Never disassemble the tool.
Maintain Laser Level
Maintain tools. If damaged, have the tool repaired
before use. Accidents may be caused by poorly
maintained tools.
jury and damage, never immerse
them.
Cleaning
Keep tool handles clean, dry and free of oil or grease.
Use only mild soap and a damp cloth to clean the
d
d
1. Place the tool within 30cm of the floor.
A free measuring distance of approximately
5m between floor and ceiling on a firm surface is
required for this check. It is suggested to install riser
block, if not already equipped.
Set tool on ground and mark the centre of the
plumb point on the ceiling (point I). Also, mark the
centre of the plumb point on the floor (point II).
tool since certain cleaning agents and solvents are
harmful to plastics and other insulated parts. Some
of these include gasoline, turpentine, lacquer thin-
ner, paint thinner, chlorinated cleaning solvents,
ammonia and household detergents containing am-
around tools.
Cleaning the Lenses
Carefully wipe the surface with a cotton swab moist-
ened with water.
Repairs
ACCESSORIES
WARNING
Use
designated accessories.
tools only with specifically
Use of any
other accessories may create risk of injury.
The maximum vertical deviation (d) is:
d max = 2X H (door opening) x ±3.18mm ÷ 10m
Example: for a door opening height of 2.05m, the
maximum permitted deviation (d) is:
dmax = 2 x 2.05m x ±3.18mm ÷ 10m = ±1.3 mm
Therefore, the measurement between points III
and IV on the upper door opening should not
exceed 1.3mm in a 2.05m doorway.
The distance between points I and III on the
ceiling is the deviation (d) of the tool. This
distance should not exceed 3.18mm (max.) at
10m For the Measuring distance of 2 x 5m =
10m, the maximum allowable deviation (d) is:
10m (33') x ±3.18mm ÷ 10m = ±3.18mm
This tool has limited serviceable parts. Do not open
housing or disassemble tool. For repairs, return the
tool, battery pack and charger to the nearest
authorised service centre.