background image

ACCURACY FIELD CHECK

NOTICE

Horizontal Height Accuracy

A

B

30cm

 

20m 

5

2. Turn the tool to 

 ON and to 

 Perpendicular 

Level & Plumb Points Mode.

3. Direct the front laser beam against the nearest

wall A and allow to self-level. Mark the centre of

the laser cross on the wall (point I).

4. Rotate the tool 180° without changing the height,

allow it to self-level, and mark the centre of the

laser cross on the opposite wall B (point II).

A

180

B

5.

A

B

30cm

6. Adjust the height of the tool (using the tripod or

7.

by adding shims, if required) to align the laser

cross directly onto point II on wall B. Allow the

tool to self-level.

Rotate the tool 180° without changing the height,

allow it to self-level, and mark the center of the

laser cross on wall A (point III). Point III should

be aligned as vertically above or below point I on

wall A as possible.

A

B

B

180

d

8.

Perform the Accuracy Field Check 

procedure immediately upon 

unboxing of each new Laser Level and before 

exposure to jobsite conditions. See "Accuracy 

Field Check" for information.

 Should any 

deviation from listed product accuracy be found, 

please contact a 

MILWAUKEE

®

 service facility. 

Failure to do so could result in rejection of warranty 

claim.

Securely mount the tool within 30cm  of wall 'A' as 

shown below.

1.

Ambient temperature gradients can impact laser 

accuracy. For accurate and repeatable results, the 

following procedure should be conducted with the 

laser elevated off the ground and placed in the 

centre of the working area.

Abusive treatment of the Laser Level, such as 

excessive impacts from repeated or high drops, 

can also lead to deviations in product accuracy.

Therefore, it is recommended to conduct the 

Accuracy Field Check procedure after any impact 

or before completing any critical jobs.

A free measuring distance of approximately 20m on 

a firm surface between two walls or structures 

(indicated as 'A' and 'B' below) is required for this 

check.

It is also suggested to mount the Laser Level to an 

appropriate tripod for easy adjustment.

Move the tool within 30cm of wall B. Allow the 

laser to self level. Align the laser cross in the 

general direction of point II on wall B.

The distance between points I and III on wall A is 

the height deviation (d) of the tool. This distance 

should not exceed 3.18mm (max.) at 10m 

(12.72mm at 40m). For the Measuring distance of 

2 x 20m = 40m, the maximum allowable deviation 

(d) is: 40m x ±3.18mm ÷ 10m = ±12.72mm

Содержание M12 CPL

Страница 1: ...OPERATOR S MANUAL Cat No M12 CPL M12 CROSS LINE PLUMB POINTS LASER WARNING To reduce the risk of injury user must read and understand operator s manual ...

Страница 2: ...er in fluid or allow a fluid to flow inside them Corrosive or conductive fluids such as seawater certain industrial chemicals and bleach or bleach containing products etc can cause a short circuit Do not charge non rechargeable batteries Do not dispose of tool or batteries with household waste material Tool and batteries that have reached the end of their life must be collected separately and retu...

Страница 3: ...pplied with your charger and battery Removing Inserting the Battery To remove the battery push in the release buttons and pull the battery pack away from the tool changing or removing accessories WARNING Always remove battery pack before To insert the battery slide the pack into the body of the tool Make sure it latches securely into place WARNING reco Only use mmended accessorie for thi s s tool ...

Страница 4: ...urns OFF the laser and locks the pen pendulum self leveling is disabled The to indicate that the projected lines are not level or plumb NOTICE The ON mode disables self leveling and therefore is not intended for projecting a level or plumb line and store the Laser Level in the protective carrying case Use the MODE button to cycle through the three laser modes Horizontal Level Line Vertical Plumb L...

Страница 5: ...ontact a MILWAUKEE service facility Failure to do so could result in rejection of warranty claim Securely mount the tool within 30cm of wall A as shown below 1 Ambient temperature gradients can impact laser accuracy For accurate and repeatable results the following procedure should be conducted with the laser elevated off the ground and placed in the centre of the working area Abusive treatment of...

Страница 6: ...oint I Do the same on Wall B Point II Move the Laser 10m toward the opposite wall and rotate the laser 180 Allow the laser to Self Level Vertical Leveling Accuracy 2 1 Vertical Plumb Perpendicular 3 Turn the tool to ON and to Line Plumb Points Mode or Level Plumb Point Mode Position the tool with the laser towards the door opening Allow the tool to self level 4 2 5m 2 5m 2 05m 5 Move the laser lev...

Страница 7: ...e of the plumb point on the floor point II tool since certain cleaning agents and solvents are harmful to plastics and other insulated parts Some of these include gasoline turpentine lacquer thin ner paint thinner chlorinated cleaning solvents ammonia and household detergents containing am around tools Cleaning the Lenses Carefully wipe the surface with a cotton swab moist ened with water Repairs ...

Страница 8: ...reet Penrose Auckland 1061 New Zealand DESIGNED BY MILWAUKEE ELECTRIC TOOL CORP PROFESSIONALLY MADE IN CHINA PRINTED IN CHINA MILWAUKEE prides itself in producing a premium quality product that is Nothing But Heavy DutyTM Your satisfaction with our products is very important to us If you encounter any problems with the operation of this tool please contact your authorised MILWAUKEE dealer For a li...

Отзывы: