background image

4

individual planes. Default is horizontal or last used 

plane(s). 

Horizontal plane

laser is ON, unlocked 

 and tilted.

Using the Laser Level

Front vertical plane

    Side vertical plane

2.

1. For best results, place the tool on a work surface

that is:

• sturdy

• level (within 4 degrees of true level)

• free of vibrations

• 90° to the work area

3.

4.

5. If the tool cannot achieve a level state (i.e., the

Turn on the tool and press the desired Plane

Selector button(s).

The tool will self-level when placed on surfaces

within 4 degrees of true level when dial is unlocked 

and on.

The tool is ready once the emitted lines are con-

tinuous and no longer moving on the work surface.

Troubleshooting

If the tool does not turn on:

Relocate or adjust the work surface.

• Ensure battery is installed properly.  Fuel gauge

should indicate remaining charge when correctly 

installed.

• Ensure battery is charged.

• 

• Use the embedded magnets to secure the laser

level to steel studs, steel beams, etc. 

*When automatically switched to power save mode

due to low battery, the tool cannot be switched back 

to normal mode until the battery is charged/replaced.

WARNING

To 

age,

reduce 

 securely 

the risk of 

mount/attach 

injury or dam

the

-

laser before starting an operation. Injury/damage 

may occur if the laser falls.

Mounting/Adjusting the Laser Level

The pivot bracket can be used to mount the laser 

level in multiple ways:

OPERATION

WARNING

To reduce the risk of injury or tem-

look directly into the laser when it is on.

CAUTION

Use of controls or adjustments or

• Use the keyhole slot to hang the laser level on the

wall with a nail or screw.

• Position the laser and/or wall mount on a stable

surface.

• Use the 1/4"-20  or 5/8"-11 threaded insert to mount

on a tripod.

• Once the level is mounted, use the micro adjustment 

  ON 

Turns ON the laser and unlocks the pendu-

lum to enable self-leveling.   

 ON 

Turns ON the laser but does not unlock the 

performance of procedures other 

-

ous radiation exposure.

NOTICE

Perform the Accuracy Field Check

procedure immediately upon unboxing 

of each new Laser Level and before exposure to 

jobsite conditions. See "Accuracy Field Check" 

for information.

 

OFF

   Turns OFF the laser and locks the pen-

pendulum (self leveling is disabled). The 

to indicate that the projected lines are not 

level or plumb.

 

 

NOTICE:

 The    ON mode disables self-

leveling and therefore is not intended for 

projecting a level or plumb line.  

and store the Laser Level in the protective 

carrying case.

To turn on the laser and unlock the pendulum, 

rotate the On/Off dial to the desired position. The 

remaining battery life will be displayed.

Do not look directly into laser 

apertures. Power on indicator will display, and 

horizontal level line will immediately be emitted 

from aperture in the laser housing.

WARNING

Ensure the tool's internal temperature is within 

specified operating ranges. If stored in excessive 

heat or cold, allow at least 2 hours to an 

appropriate ambient temperature between -10°C 

to 40°C before turning on the tool.

If problem persists, please contact a 

MILWAUKEE

®

 

service facility for support.

Содержание M12 3PLA

Страница 1: ...OPERATOR S MANUAL Cat No M12 3PLA M12 360 3 PLANE LASER WARNING To reduce the risk of injury user must read and understand operator s manual...

Страница 2: ...ength may not hold on thin metal surfaces causing the tool to fall Maintain labels and nameplates These carry important information If unreadable or missing contact MILWAUKEE for a replacement ADDITIO...

Страница 3: ...G reco Only use mmended accessorie for thi s s tool Others may be hazardous Power Save Use power save mode to extend the battery run time Power save mode is indicated by dimmed laser beams and the Pow...

Страница 4: ...m look directly into the laser when it is on CAUTION Use of controls or adjustments or Use the keyhole slot to hang the laser level on the wall with a nail or screw Position the laser and or wall moun...

Страница 5: ...y deviation from listed product accuracy be found please contact a MILWAUKEE service facility Failure to do so could result in rejection of warranty claim Ambient temperature gradients can impact lase...

Страница 6: ...s only with specifically Use of any other accessories may create risk of injury A door opening with approximately 2 5m of space on each side of the opening is required for this check Securely mount th...

Страница 7: ......

Страница 8: ...a Toll Free Telephone Number 1300 645 928 New Zealand Toll Free Telephone Number 0800 645 928 or visit milwaukeetool com au milwaukeetool co nz Please refer to Australian and New Zealand warranty supp...

Отзывы: