background image

4

Selecting the Color Palette

Select one of three color palettes to suit your needs. 

Turn the tool on, then use the arrow ◄► buttons to 

step through the palettes.

RAINBOW

 

Shows a very wide range of 

temperatures

IRON-BOW

 

Useful for revealing small 

temperature differences

HIGH CONTRAST

   Shows the most detail

HOT/COLD   Indicator marks

To  turn  the  HOT/COLD  Indicator  marks  on  or  off 

while  taking  a  temperature  measurement,  press 

the OK button during live view. Red (hot) and blue 

(cold)  target  marks  locate  the  highest  and  lowest 

temperatures in the display area.

Taking a Temperature Measurement

1. 

Insert a battery pack and turn

 

on the tool.

2. Point the tool at the target. 

The Target Temperature is dis-

played at the top of the screen.

3. To activate the laser guides, 

pull the trigger softly (less than 

half-way). See "83:1 Distance 

to Spot Ratio".

4. 

Turn the HOT/COLD 

 indi-

cator marks on or off, or toggle 

through the different palettes 

to get the desired image on the display. 

5. 

The center temperature is affected by the material 

of the target, and can be adjusted by changing the 

Emissivity. See "Selecting the Emissivity".

Using the Laser Indicators

Use the lasers to frame up the target area. The 

lasers correlate to the temperature crosshair on the 

display. Lasers are accurate to 3" @ 50'. The target 

temperature is taken in between the laser indicators, 

and sized according to the following chart. 

83:1 Distance to Spot Ratio

At 83' away, 

spot is ~Ø 1'

At 25' away, 

spot is ~Ø 4" At 3' away, 

spot is ~Ø 1/2"

NOTE:

 A quick change in temperature (>10°F) can 

affect  the  meter’s  readings. Always  allow  the  me

-

ter  to  reach  its  stable  operating  temperature  after 

startup and before use (5 to 30 minutes, depending 

on environment).

Viewing Images on Another Device

Saved images can be transferred to another device in 

two ways - by removing the SDHC card and inserting 

it into another device, or by connecting the Infrared 

Camera directly to another device. This allows the 

images to be available for things like email, insert

-

ing into documents, or for use in the MILWAUKEE 

Thermal Imaging Software.

To transfer the SDHC card, follow the Removing/

Installing the SDHC Memory Card instructions. To 

transfer pictures directly, connect the micro USB 

cord to the Infrared Camera micro USB port. Con-

nect the other end to your device. Turn the Infrared 

Camera on. 

Two  types  of  files  are  created  for  each  image. A 

".PNG" file is created for general use. A ".DAT" file 

is created for use in the MILWAUKEE Thermal Imag

-

ing Software.

MILWAUKEE Thermal Imaging Report 

Software

The MILWAUKEE Thermal Imaging Report Software 

is available for download from the 2258-21 product 

page at www.milwaukeetool.com. 

Refer to the Thermal Imaging Report software 

manual PDF for training.

Personal Settings 

To set up the Infrared Camera to your personal pref-

erences, turn on the tool and press the Settings   

button. Use the arrow ▲▼◄► buttons and OK but

-

ton to toggle and select the desired settings.

LASER 

Turn the laser guides ON/OFF

CROSSHAIR 

Turn the crosshair ON/OFF

EMISSIVITY  

Select the Emissivity of the 

target (see "Selecting the 

Emissivity")

UNITS 

Select Fahrenheit (F°) or 

Celsius (C°)

TIME 

Set the time

DATE 

Set the date

FORMAT 

Select the Time and Date 

formats

LANGUAGE 

Select the display language

DELETE ALL 

Delete all images on the 

SDHC card

FACTORY RESET 

Return Infrared Camera to 

original factory settings

SYSTEM INFO 

Display system information

OPERATION

Turning the Tool ON/OFF 

Press the Power 

 button to turn the tool on and off.

Turning the Worklight   ON/OFF

Press the Worklight   button to turn the worklight 

on and off.

Optimizing Thermal Images

Use the emissivity settings, palette selection, and 

HOT/COLD indicators to optimize your thermal im

-

ages to your needs.

Содержание 2258-20

Страница 1: ...MANUAL MANUEL de L UTILISATEUR MANUAL del OPERADOR WARNING To reduce the risk of injury user must read and understand operator s manual AVERTISSEMENT Afin de r duire le risque de blessures l utilisate...

Страница 2: ...or metal building during the summer Do not remove or deface labels Maintain labels and nameplates These carry important information If unreadable or missing contact a MILWAUKEE service facility for a...

Страница 3: ...gs for more information SET UP WARNING Recharge only with the charger specified for the battery For spe cific charging instructions read the operator s manual supplied with your charger and battery In...

Страница 4: ...sferred to another device in two ways by removing the SDHC card and inserting it into another device or by connecting the Infrared Camera directly to another device This allows the images to be availa...

Страница 5: ...charger and remove the battery pack from the charger or tool before performing any maintenance Never disassemble the tool battery pack or charger Contact a MILWAUKEE service facility for ALL repairs...

Страница 6: ...LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES WRITTEN OR ORAL TO THE EXTENT PERMITTED BY LAW MILWAUKEE DISCLAIMS ANY IMPLIED WARR...

Страница 7: ...haute fr quence et s il n est pas install conform ment aux pr sentes instructions peut causer le brouillage des communica tions radio Toutefois il n existe aucune garantie que le brouillage ne se prod...

Страница 8: ...e de vie de la pile l imageur thermique passe en mode veille apr s 5 minutes d inactivit Le mode veille maintient une condition d tat pr t de pr chauffage mais utilise peu la puis sance de la pile Po...

Страница 9: ...icateur CHAUD FROID Pour activer ou d sactiver les rep res de l indicateur CHAUD FROID pendant la mesure de la temp ra ture appuyer sur le bouton OK pendant la vue en direct Les rep res cibles rouge c...

Страница 10: ...otre centre de services le plus proche L appareil y sera envoy pour y tre test et il vous sera retourn avec la documentation ad quate Entretien de l outil Gardez l outil la batterie et le chargeur en...

Страница 11: ...LA LOI LA DUR E DE CES GARANTIES IMPLICITES EST LIMIT E LA P RIODE APPLICABLE DE LA GARANTIE EXPRESSE TEL QUE CELA EST D CRIT PR C DEMMENT CERTAINS TATS ET PROVINCES NE PERMETTANT PAS DE LIMITATION D...

Страница 12: ...ra usa y puede irradiar energ a de radiofrecuencia y si no se instala y se utiliza de acuerdo con las instruc ciones puede ocasionar interferencia nociva con las comunicaciones por radio Sin embargo n...

Страница 13: ...alla durante 3 segundos antes de que la c mara t rmica se apague Funciones de ahorro de energ a Para preservar la duraci n de la bater a la c mara t rmica entra en modo Dormir despu s de 5 minutos de...

Страница 14: ...ules fr o localizan las temperaturas m s altas y m s bajas en el rea de la pantalla C mo medir la temperatura 1 Inserte una bater a y encienda la herramienta 2 Dirija la herramienta hacia el objetivo...

Страница 15: ...rramienta se enviar a pruebas y se le devolv er junto con la documentaci n correspondiente Mantenimiento de la herramienta Adopte un programa regular de mantenimiento y mantenga sus bater as y cargado...

Страница 16: ...ESPONSABILIDAD POR DA OS INCIDENTALES O EMERGENTES POR LO QUE LA ANTERIOR LIMITACI N O EXCLUSI N PODR A NO APLICARSE EN SU CASO ESTAGARANT AES EXCLUSIVAY REEMPLAZATO DAS LAS DEM S GARANT AS EXPRESAS E...

Отзывы: