General installation and maintenance instructions 

HOSPITAIR PACK S (MV) - 11 bar

 

 

 

Manual N° 520003 version 5 

12/2016 

Page 16/17 

 

 

Guidance and manufacturer’s declaration – electromagnetic immunity - for ME equipment and ME systems that are not life-

supporting

 

The units

 

with PROCOM2 automate is intended for use in the electromagnetic environment specified below. The customer or the user 

of the units

 

with PROCOM2 automate should assure that it is used in such an electromagnetic environment. 

Immunity test

 

IEC 60601 test level

 

Compliance level

 

Electromagnetic environment 

– 

guidance

 

 
 
 
 
 
 
 
 
 
 
 

Conducted RF 
IEC 61000-4-6 

 
 
 
 

Radiated RF 

IEC 61000-4-3 

 
 
 
 
 
 
 
 
 
 
 

3 Vrms  

150 kHz to 80 MHz 

 
 
 
 

3 V/m  

80 MHz to 2,5 GHz 

 
 
 
 
 
 
 
 
 
 
 

3 Vrms 

 
 
 
 
 

3 V/m 

Portable and mobile RF communications 
equipment should be used no closer to any part of 
the units

 

with PROCOM2 automate, including 

cables, than the recommended separation 
distance calculated from the equation applicable 
to the frequency of the transmitter. 
 

Recommended separation distance 

 
d = 

1.16 

P  

 
 
 
 
d = 

1.16 

de 80 MHz à 800 MHz 

 

d =  

2.33 

P

 de 800 MHz à 2,5 GHz 

 
where 

is the maximum output power rating of 

the transmitter in watts (W) according to the 
transmitter manufacturer and 

is the 

recommended separation distance in meters (m). 
 
Field strengths from fixed RF transmitters, as 
determined by an electromagnetic site survey (1) 
should be less than the compliance level in each 
frequency range. (2) 
 
Interference may occur in the vicinity of equipment 
marked with the following symbol: 
 

 

NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. 
 
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from 
structures, objects and people.  
 
(1) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, 
amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the 
electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field 
strength in the location in which the units

 

with PROCOM2 automate is used exceeds the applicable RF compliance level above the 

units

 

with PROCOM2 automate should be observed to verify normal operation. If abnormal performance is observed, additional 

measures may be necessary, such as re-orienting or relocating the units

 

with PROCOM2 automate. 

 
(2) Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. 

 

Содержание HOSPITAIR PACK S MVA 8

Страница 1: ...RULES see manual n 511927 Spare parts list and maintenance instructions for compressors First apposition of the EC marking 2009 This document must not be disclosed or reproduced without permission fr...

Страница 2: ...ESCRIPTION OF THE OPERATION 5 INSTALLATIONS 7 3 5 DIMENSIONS 7 SECTION 4 ELECTRIC POWER SUPPLY 8 4 1 COMPRESSOR POWER SUPPLY 8 4 2 CONNECTION BETWEEN COMPRESSOR AND PROCOM 2 OF PRO2XY 8 4 3 SUMMARY OF...

Страница 3: ...in a safe place and to dispose of it with due care for the environment Dustbin on wheels barred of a cross symbol This symbol indicates that the equipment should not be thrown with domestic waste and...

Страница 4: ...2 Specification plates Type Hospitair units Serial number Air dryer type Serial number SECTION 2 CHOICE OF ROOM The unit must be located in a clean non humid non saline dustless and ventilated local w...

Страница 5: ...38 37 31 820 1 00 13 500 700 x 700 The person in charge of the installation has overall responsibility of the product environment requirements He is also in charge of setting up methods of struggle ag...

Страница 6: ...he pressure before the air treatment unit Then the air enters the filtration chain see the description in the manual concerning the filtration chain At the filtration chain output the air is then stor...

Страница 7: ...order given by the oxygen generator 3 4 4 Emergency stop compressor Use the emergency button only in extreme necessity because it stops suddenly the compressor and if the compressor is on charge oil c...

Страница 8: ...s HOSPITAIR PACK S MVA 8 MVB 12 MVB 16 HOSPITAIR PACK S MVC 19 MVC 23 HOSPITAIR PACK S MVD 31 MVE 38 MVE 46 3 5 2 Vertical air receivers 500 1000 litres E B A C F 1 2 Soupape Outlet Inlet Pressure gau...

Страница 9: ...mpliance with the legislation and regulations in force in your country The wire sections are given for information to 5A mm2 Even so the sections shall be defined by taking contacts with the wire prov...

Страница 10: ...report The connection between Alarm report on automate units must be done by the person in charge of the Installation He must control the compliance wiring and proper operation during the final accept...

Страница 11: ...rainage system OWAMAT separator used to separate oil and water In compliance with Law No 76 663 dated 19 July 1976 relating to installations classified for protecting the environment Law 92 3 dated 3...

Страница 12: ...pen the network outlet valve gradually SECTION 7 CLEANING AND MAINTENANCE IMPORTANT For this operation use all necessary protective measures gloves mask overalls etc then destroy contaminated consumab...

Страница 13: ...to stop Check the compressor discharge time before it stops completely 10 to 15 seconds 7 3 Safety relief valve When a relief valve with discharge line operates and must be tested no persons may stand...

Страница 14: ...to avoid all forced and tensions and to damp out all vibrations even non visible The base of the receiver will have to support the weight of the receiver including in situation of tests In performing...

Страница 15: ...g the compressed air unit object of this technical manual are protected by relief valves as indicated in the table hereafter Component Pressure setting bar Location of the safety relief valve Compress...

Страница 16: ...should assure that it is used in such an electromagnetic environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2...

Страница 17: ...ufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey 1 should be less than the compliance level...

Страница 18: ...o the maximum output power of the communications equipment Separation distance according to frequency of transmitter Rated maximum output power of transmitter W m 150 kHz to 80 MHz d 1 16 P 80 MHz to...

Страница 19: ......

Страница 20: ......

Отзывы: