Service Connections
PELLERIN MILNOR CORPORATION
2.1.
Piped Inlet Specifications
Table 1: Piped Inlets
Connection Description
Source Requirements
Piping Requirements, Comments
Cold water inlet
3/4" NPT
Hot water inlet
Third water inlet (optional)
Hot water for supply
Air supply
1/4" NPT
Steam inlet (if equipped)
3/4" NPT
Pipe material per plumbing code
Liquid supply inlet
3/8" or 1/2"
Flexible tubing as supplied by the
chemical supplier
2.2.
Piped Outlet Specifications
Table 2: Outlets
Connection Description
Destination Requirements or Description
Piping Specifications
Drain
3" pipe socket joint, unrestricted gravity feed to
sewer (external back pressure may extend wash
times - Do not reduce)
Rubber hose, PVC or other
approved material per
plumbing code
Vent
3"
3.
Power Connections and Precautions
WARNING 3 : Electrocution and Electrical Burn Hazards
—Contact with high voltage
will electrocute or burn you. Power switches on the machine and the control box do not eliminate
these hazards. High voltage is present at the machine unless the main machine power disconnect
is off.
• Do not service machine unless qualified and authorized.
Notice 4 : Machine Damage Hazards
—Voltage fluctuations of more than 10% above or
below the specified voltage for your machine can damage electrical components, especially
motors.
• Any such conditions should be corrected prior to commissioning your machine.
The customer must furnish a remotely mounted disconnect switch with lag type fuses or circuit
breakers, and wiring between the electrical service box and the junction box on the machine. The
sizes of these fuses and wires, along with the motor fuses supplied with the machine, depend on
the machine voltage. See the fuse and wire sizing information in the schematic manual and on the
machine nameplate. See dimensional drawings in this manual for electrical connection locations.
1. Electrical connections must be made by a competent electrician.
2. See fuse and wire sizing information in the schematic manual and on the machine nameplate.
If the wire runs more than 50 feet, increase by one wire size for each additional 50 feet.
3. Only use Bussman Fusatron FRN (up to 250V), FRS (up to 600V) or similar lag fuses, the
nameplate fuse sizes must not be applied to standard fuses.
4. Stinger leg, if any, must be connected to terminal L3, never to terminals L1 or L2.
5. Make power and liquid supply electrical connections within junction boxes on the rear of the
machine.
Содержание 36026X8J
Страница 12: ...Safety Suspended Open Pocket Non tilting Washer Extractors PELLERIN MILNOR CORPORATION End of BIUUUS27 ...
Страница 24: ......
Страница 25: ...Section 1 Service and Maintenance ...
Страница 31: ......
Страница 52: ......
Страница 63: ...Section 2 Drive Assemblies ...
Страница 65: ......
Страница 69: ......
Страница 73: ...Section 3 Suspension ...
Страница 80: ......
Страница 81: ...Section 4 Shell and Door Assemblies ...
Страница 87: ...Section 5 Water and Steam Piping and Assemblies ...
Страница 95: ......
Страница 97: ......
Страница 99: ......
Страница 104: ......
Страница 105: ...Section 6 Chemical Supply Assemblies ...
Страница 117: ...Section 7 Control and Sensing Assemblies ...
Страница 120: ......
Страница 121: ...Section 8 Pneumatic Assemblies ...
Страница 123: ...Section 9 Dimensional Drawings ...
Страница 124: ......
Страница 125: ......
Страница 126: ......