OM-254 449 Page 24
SECTION 6
−
MAINTENANCE & TROUBLESHOOTING
6-1. Routine Maintenance
!
Disconnect power
before maintaining.
.
Maintain more often
during severe conditions.
n
= Check
Z
= Change
~
= Clean
l
= Replace
* To be done by Factory Authorized Service Agent
Reference
Each
Use
n
Gas/Air Pressure
n
Torch Tip, Electrode,
And Shield Cup
Every
Week
n
Shield Cup Shutdown
System
Every
3
Months
l
Damaged Or Unreadable
Labels
~
Air Filter/Regulator
l
Cracked Parts
n
l
Gas/Air Hose
n
l
Torch Body, Cable
Every
6
Months
OR
~
Inside Unit
6-2. Shield Cup Shutdown System
Ref. 253 554-A
1
Torch Shield Cup
Turn Power On and loosen shield
cup. If shutdown system works
properly, Cup light comes on. If not,
immediately turn Off power and
have Factory Authorized Service
Agent check unit.
If system works properly, retighten
cup and reset power.
1
.
Power must be reset whenever the cup shutdown system
is activated.
Always turn Off power when changing or
checking consumables. Do NOT overtighten torch
shield cup. Gently finger tighten cup onto torch.