OM-254 449 Page 20
4-8. Connecting And Disconnecting 60 Ampere (XT60) Torch On Spectrum 875
And Spectrum 875 Auto-Line, And Using Trigger Safety Lock
!
Turn off power source and
disconnect input power.
1
Torch Connector
2
Quick Connect Collar
3
Nipple
4
Receptacle
5
Securing Pin
To connect torch:
Push torch connector onto
receptacle and quick connect until
collar secures nipple.
Rotate securing pin clockwise to
lock connector to unit.
To disconnect torch:
Rotate securing pin counterclock-
wise to unlock connector from unit.
Push quick connect collar back
towards unit to release nipple, and
pull torch connector away from unit.
.
Use supplied hook and loop
strap to manage torch and
work cables.
6
Trigger
805 161-A / Ref. 256 001-A
2
1
3
4
5
Trigger Locked
Trigger Unlocked