OM-254 449 Page 12
3-5. XT40 Torch Specifications
Torch
−
The XT40 torch is intended for handheld use only. The torch conforms to IEC 60974-7 when used with the Spectrum 625
X-TREME. Do not use this torch in combination with any other machines.
Gas Type
Air or Nitrogen
−−
−−
Gas Quality
Clean, moisture
−
free,
oil
−
free
−−
−−
Gas Inlet Flow and Pressure
6.0 SCFM (170 L/min)
90 PSI (621 kPa)
Min
120 PSI (827
kPa) Max
Gas Filtering
Particulates to 5 microns
−−
−−
Cooling Method
Air
−−
−−
Duty Cycle of Torch
100% at 40 Amps
−−
−−
Rating of Electrical Controls (Trigger)
30 VDC at .1 Amps
−
−
−
−
Rating of Electrical Controls (Cup)
30 VDC at 1 Amp
−
−
−
−
Approved Systems
Spectrum 625 X-TREME w/XT40 torch
Trigger Protection
Safety trigger guard
Safety Devices
Safety interlock devices shut down power source
Rated Capacity (edge start)
5/8 in. at 13 ipm (330 mm/min)*
−−
−−
Sever Cut Capacity (edge start)
7/8 in. at 4 ipm (102 mm/min)*
−−
−−
Pierce Capacity
5/16 in.
−−
−−
*Travel speeds are approximately 80% of maximum.
Weight
2.5 lb (1.1 kg) 12 ft (3.7 m)
3.4 lb (1.5 kg) 20 ft (6.1 m)
−
−
−
−
Requirements for the torch connection
S
Use only compressed air which is free from dirt, oil, and water.
S
Ensure that the connections are properly assigned and tightened.
S
For torch replacement, see Miller torch manual Part No. OM-254449
S
Ensure correct air pressure (flow pressure) and airflow (volume) are set. Insufficient airflow can lead to the torch overheating.
3-6. XT40 Torch Dimensions
Ref. 253 554-A
1-3/16 in.
(30 mm)
8-3/4 in.
(222 mm)
1-1/2 in.
(38 mm)
Содержание XT30C