INSTALLATION
5-1. Serial Number And Rating Label Location
The serial number for this product is located on
the front.
The rating information for this product is located on the back. Use rating label to determine
rated output. For future reference, write serial number in space provided on back cover of this manual.
!
Do not move or operate unit
where it could tip.
!
Do not lift unit from end.
!
Do not weld on base. Welding
on base can cause fuel tank fire
or explosion. Bolt unit down
using holes provided in base.
!
Always securely fasten weld-
ing generator onto transport
vehicle or trailer and comply
with all DOT and other applica-
ble codes.
NOTICE
−
Do not install unit where air
flow is restricted or engine may over-
heat.
See Section 4-2 for lifting eye rat-
ing.
Mounting:
!
Do not mount unit by support-
ing the base only at the four
mounting holes. Do not use
flexible mounts. Use cross-
supports to adequately sup-
port unit and prevent damage
to base.
1
Cross-Supports
Mount unit on flat surface or use
cross-supports to support base, see
Section 4-2.
install2 2008-01
−
Ref. 800 652 / Ref. 800 477-A / 803 274-A / 804 712
OR
18 in.
(460 mm)
18 in.
(460 mm)
18 in.
(460 mm)
18 in.
(460 mm)
18 in.
(460 mm)
OR
Movement
Location / Airflow Clearance
5-2. Installing Welding Generator
Mounting
OR
1