4-10. Connecting Remote Control
Ref. 802 295 / Ref. S-0004-A / S-0750
Y
Turn off power before con-
necting to receptacle.
1
Remote 14 Receptacle RC8
Connect remote control to RC8. If
plug does not fit, wire cord to
terminal strip 1T.
Y
Turn Off power before open-
ing terminal strip cover.
2
Terminal Strip 1T
3
Remote Control Cord
4
Strain Relief (Customer
Supplied)
Secure cord in strain relief.
Reinstall and secure access panel.
Close door.
1
OR
OR
A
J
B
K
I
C L N
H
D M
G
E F
3
2
4
4-11. Electrical Service Guide
A. 1000 Ampere Rated Welding Output
60 Hz
Input Voltage
230
460
575
Input Amperes At Rated Output
180
90
72
Max Recommended Standard Fuse Rating In Amperes
1
Time-Delay
2
225
110
90
Normal Operating
3
250
125
110
Min Input Conductor Size In AWG
4
3/0
3
4
Max Recommended Input Conductor Length In Feet (Meters)
204
(62)
337 (103)
438 (134)
Min Grounding Conductor Size In AWG
4
4
6
6
Reference: 1999 National Electrical Code (NEC)
1 Consult factory for circuit breaker applications.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.