![Miller S-74 MPa Plus Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/miller/s-74-mpa-plus/s-74-mpa-plus_technical-manual_1796011037.webp)
TM-273245 Page 33
S-74 MPa Plus
for PC2
information
244221-G
Voltage Readings
a)
Tolerance
−
±
10% unless specified
b)
Reference
−
DC Voltage to RC3-3 (Unless noted)
c)
Reference
−
AC Voltage to RC5-2 (Unless noted)
V1
+2 to +24 volts DC when triggered or jogged
V2
+24 volts AC when triggered or purged
V3
+24 volts AC - IN
V4
+24 volts AC contactor
V5
+1 volt/100 amps current feedback
V6
+1 volt/+10 volts DC voltage feedback
V7
0 to +10 volts DC command voltage/arc
length
V8
0 to +10 volts DC wirefeed speed command
V9
+15 volts DC when triggered
V10
+15 volts DC when AlumaPro Plus gun is
triggered
V11
+5 volts DC gun command reference
V12
0 to +5 volts DC gun command pot
V13
+1.8 volts DC gun sense AlumaPro Plus
V14
+2 to +22 volts DC push-pull motor voltage
V15
+3.5 VDC in MIG mode, +2.5 VDC in Pulse
V16
+1.5 VDC or +7.2 VDC at rest, +3.4
−
4 VDC
when running
V17
+0.35 VDC or +3 VDC at rest, +1.6 VDC
when running
Test Equipment Needed: