![Miller S-74 MPa Plus Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/miller/s-74-mpa-plus/s-74-mpa-plus_technical-manual_1796011015.webp)
TM-273245 Page 11
S-74 MPa Plus
4-4. 14-Pin Plug Information For Connecting Wire Feeder To Power Source
Pin*
Pin Information
A
J
B
K
I
C
L
N
H
D
M
G
E
F
A
24 volts AC with respect to socket G.
B
Contact closure to A completes 24 volts AC contactor control circuit.
G
Circuit common for 24 volts AC circuit.
C
+10 volts DC input from power source to wire feeder with respect to socket D.
D
Remote control circuit common.
E
0 to +10 volts DC output signal from wire feeder to power source with respect to socket D.
H
Voltage feedback; 0 to +10 volts DC, 1 volt per 10 arc volts.
F
Current feedback; 0 to +10 volts DC, 1 volt per 100 amperes.
L
0 to +10 volts DC output signal from wire feeder to power source with respect to socket N.
M
CC/CV select 0 to +10 volts DC.
N
Feeder common.
K
Not used.
*The remaining pins are not used.
4-5. Wire Type, Size, And Optimal Wire Feed Speed Table
Motor Speed
Wire Type
Wire Size
Rated Speed Range (per IEC 60974
−
5)
Standard
All
.035 To .062 in. (0.9 To 1.57 mm)
55 To 770 ipm (1.4 To 19.6 mpm)
Standard
All
5/64 in. (2 mm)
55 To 700 ipm (1.4 To 17.8 mpm)
Notes