OM-236 891 Page 19
5-2. Remote 14 Accessory Receptacle Information
If a remote control is connected to the Remote 14 receptacle, the unit will automatically adjust output control to a primary/secondary configuration. In
this configuration, the Amperage Adjust knob on the unit becomes the primary and sets the maximum amperage output of the unit. The remote control
becomes the secondary and provides an amperage range of 0 to 100% based on the Amperage Adjust knob setting.
.
The Remote 14 receptacle is factory set to be active in TIG mode only. As an option, this receptacle may also be enabled in Stick mode (see Section
5-3).
A
J
B
K
I
C L N
H
D M
G
E
F
805 143--A
Socket*
Socket Information
15 VOLTS DC
A
15 volts DC.
B
Contact closure to A completes 15 volts DC
contactor control circuit.
REMOTE
CONTROL
C
Output to remote control; +10 volts DC.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from
remote control.
GND
K
Chassis common.
*The remaining sockets are not used.