OM-287504 Page 13
4-2. Selecting Cable Sizes*
NOTICE
−
The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source
is 30 m (100 ft) from the workpiece, the total cable length in the weld circuit is 60 m (2 cables x 30 m). Use the 60 m (200 ft) column to determine
cable size.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
30 m (100 ft) or Less
45 m (150
ft)
60 m (200 ft)
70 m (250
ft)
90 m (300
ft)
105 m (350
ft)
120 m (400
ft)
Welding
Amperes
10
−
60%
Duty
Cycle
mm
2
(AWG)
60
−
100%
Duty Cycle
mm
2
(AWG)
10
−
100% Duty Cycle
mm
2
(AWG)
100
20 (4)
20 (4)
20 (4)
30 (3)
35 (2)
50 (1)
60 (1/0)
60 (1/0)
150
30 (3)
30 (3)
35 (2)
50 (1)
60 (1/0)
70 (2/0)
95 (3/0)
95 (3/0)
200
30 (3)
35 (2)
50 (1)
60 (1/0)
70 (2/0)
95 (3/0)
120 (4/0)
120 (4/0)
250
35 (2)
50 (1)
60 (1/0)
70 (2/0)
95 (3/0)
120 (4/0)
2x70 (2x2/0)
2x70 (2x2/0)
300
50 (1)
60 (1/0)
70 (2/0)
95 (3/0)
120 (4/0)
2x70 (2x2/0)
2x95 (2x3/0)
2x95 (2x3/0)
350
60 (1/0)
70 (2/0)
95 (3/0)
120 (4/0)
2x70 (2x2/0)
2x95 (2x3/0)
2x95 (2x3/0)
2x120 (2x4/0)
400
60 (1/0)
70 (2/0)
95 (3/0)
120 (4/0)
2x70 (2x2/0)
2x95 (2x3/0)
2x120 (2x4/0) 2x120 (2x4/0)
500
70 (2/0)
95 (3/0)
120 (4/0)
2x70 (2x2/0)
2x95 (2x3/0)
2x120 (2x4/0)
3x95 (3x3/0)
3x95 (3x3/0)
600
95 (3/0)
120 (4/0)
2x70 (2x2/0)
2x95 (2x3/0)
2x120 (2x4/0)
3x95 (3x3/0)
3x120 (3x4/0) 3x120 (3x4/0)
*
This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
***For distances longer than those shown in this guide, see AWS Fact Sheet No. 39, Welding Cables, available from the American Welding
Society at http://www.aws.org.
Milan Ref. S-0007-M 2017
−
08
4-3. Weld Output Terminals
!
Turn off power before connecting
to weld output terminals.
!
Do not use worn, damaged,
undersized, or repaired cables.
1
Electrode Weld Output Terminal
(
−
) Negative Weld Output Terminal
2
Work Weld Output Terminal
(+) Positive Weld Output Terminal
3
Remote 14 Receptacle
2
Ref. 956172374_4_A
3
1
Содержание MigMatic S400i
Страница 4: ......
Страница 5: ......
Страница 33: ...OM 287504 Page 27 956172379 A PC5 PC5 HD1 HD2 PC1 PC8...
Страница 34: ...OM 287504 Page 28 PC2 PC2 PC4 PC7 FM FM FM FM Figure 7 2 Circuit Diagram for Migmatic S400iP...
Страница 35: ...OM 287504 Page 29 956172380 A PC5 PC5 PC1 PC8 HD2 HD1...
Страница 36: ...OM 287504 Page 30 PC4 PC7 PC2 PC2 FM FM FM FM Figure 7 3 Circuit Diagram for Migmatic S500i...
Страница 37: ...OM 287504 Page 31 956172381 A PC1 PC5 PC5 HD1 HD2 PC8...
Страница 40: ...Notes Securely connect work clamp to a clean area close to the weld joint Welding Tip...
Страница 41: ...Notes...
Страница 42: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...