EMF DATA SHEET FOR ARC WELDING POWER SOURCE
Product/Apparatus Identification
Product Stock
Number
MigMatic S500i
059015056
MigMatic S400iP
059015055
Migmatic S400i
059015054
Compliance Information Summary
Applicable regulation
Directive 2014/35/EU
Reference limits
Directive 2013/35/EU, Recommendation 1999/519/EC
Applicable standards
IEC 62822
−
1:2016, IEC 62822
−
2:2016
Intended use
☐
for occupational use
☐
for use by laymen
Non
−
thermal effects need to be considered for workplace assessment
☒
YES
☐
NO
Thermal effects need to be considered for workplace assessment
☐
YES
☒
NO
☒
Data is based on maximum power source capability (valid unless firmware/hardware is changed)
☐
Data is based on worst case setting/program (only valid until setting options/welding programs are changed)
☐
Data is based on multiple settings/programs (only valid until setting options/welding programs are changed)
Occupational exposure is below the Exposure Limit Values (ELVs)
☒
YES
☐
NO
for health effects at the standardized configurations
(if NO, specific required minimum distances apply)
Occupational exposure is below the Exposure Limit Values (ELVs)
☐
n.a
☒
YES
☐
NO
for sensory effects at the standardized configurations
(if applicable and NO, specific measures are needed)
Occupational exposure is below the Action Levels (ALs) at the
☐
n.a
☒
YES
☐
NO
standardized configurations
(if applicable and NO, specific signage is needed)
EMF Data for Non-thermal Effects
Exposure Indices (EIs) and distances to welding circuit (for each operation mode, as applicable)
Head
Trunk
Limb (hand)
Limb (thigh)
Sensory
Effects
Health
Effects
Standardized distance
10 cm
10 cm
10 cm
3 cm
3 cm
ELV EI @ standardized distance
0.08
0.06
0.09
0.05
0.11
Required minimum distance
1 cm
1 cm
1 cm
1 cm
1 cm
Distance where all occupational ELV Exposure Indices fall below 0.20 (20%)
2 cm
Distance where all general public ELV Exposure Indices fall below 1.00 (100%)
82 cm
Tested by:
Joe Krueger
Date tested:
2019
−
12
−
06
XXXXXX‐A
Содержание MigMatic S400i
Страница 4: ......
Страница 5: ......
Страница 33: ...OM 287504 Page 27 956172379 A PC5 PC5 HD1 HD2 PC1 PC8...
Страница 34: ...OM 287504 Page 28 PC2 PC2 PC4 PC7 FM FM FM FM Figure 7 2 Circuit Diagram for Migmatic S400iP...
Страница 35: ...OM 287504 Page 29 956172380 A PC5 PC5 PC1 PC8 HD2 HD1...
Страница 36: ...OM 287504 Page 30 PC4 PC7 PC2 PC2 FM FM FM FM Figure 7 3 Circuit Diagram for Migmatic S500i...
Страница 37: ...OM 287504 Page 31 956172381 A PC1 PC5 PC5 HD1 HD2 PC8...
Страница 40: ...Notes Securely connect work clamp to a clean area close to the weld joint Welding Tip...
Страница 41: ...Notes...
Страница 42: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...