background image

OM-287504 Page 4

H.F. RADIATION can cause interference.

High-frequency (H.F.) can interfere with radio

navigation, safety services, computers, and

communications equipment.

Have only qualified persons familiar with electronic equipment

perform this installation.

The user is responsible for having a qualified electrician prompt-

ly correct any interference problem resulting from the installa-

tion.

If notified by the FCC about interference, stop using the

equipment at once.

Have the installation regularly checked and maintained.

Keep high-frequency source doors and panels tightly shut, keep

spark gaps at correct setting, and use grounding and shielding to

minimize the possibility of interference.

ARC WELDING can cause interference.

Electromagnetic energy can interfere with

sensitive electronic equipment such as

computers and computer-driven equipment

such as robots.

Be sure all equipment in the welding area is electromagnetically

compatible.

To reduce possible interference, keep weld cables as short as

possible, close together, and down low, such as on the floor.

Locate welding operation 100 meters from any sensitive elec-

tronic equipment.

Be sure this welding machine is installed and grounded

according to this manual.

If interference still occurs, the user must take extra measures

such as moving the welding machine, using shielded cables,

using line filters, or shielding the work area.

1-4. California Proposition 65 Warnings

WARNING: This product can expose you to chemicals in-

cluding lead, which are known to the state of California to

cause cancer and birth defects or other reproductive

harm.

For more information, go to www.P65Warnings.ca.gov.

1-5. Principal Safety Standards

Safety in Welding, Cutting, and Allied Processes,

 American Welding

Society standard ANSI Standard Z49.1. Website: www.aws.org.

Safe Practice For Occupational And Educational Eye And Face Protec-

tion,

 ANSI Standard Z87.1 from American National Standards Institute.

Website: www.ansi.org.

Safe Practices for the Preparation of Containers and Piping for Welding

and Cutting,

 American Welding Society Standard AWS F4.1 from Glob-

al Engineering Documents. Website: www.global.ihs.com.

Safe Practices for Welding and Cutting Containers that have Held Com-

bustibles,

 American Welding Society Standard AWS A6.0 from Global

Engineering Documents. Website: www.global.ihs.com.

National Electrical Code,

 NFPA Standard 70  from National Fire Protection

Association. Website: www.nfpa.org and www. sparky.org.

Safe Handling of Compressed Gases in Cylinders,

 CGA Pamphlet P-1

from Compressed Gas Association. Website:www.cganet.com.

Safety in Welding, Cutting, and Allied Processes,

 CSA Standard

W117.2 from Canadian Standards Association.

Website: www.csagroup.org.

Standard for Fire Prevention During Welding, Cutting, and Other Hot

Work,

 NFPA Standard 51B from National Fire Protection Association.

Website: www.nfpa.org.
OSHA

 Occupational Safety and Health Standards for General Industry

,

Title 29, Code of Federal Regulations (CFR), Part 1910.177 Subpart N, Part

1910 Subpart Q, and Part 1926, Subpart J. Website: www.osha.gov.
OSHA 

Important Note Regarding the ACGIH TLV, Policy Statement on

the Uses of TLVs and BEIs.

 Website: www.osha.gov.

Applications Manual for the Revised NIOSH Lifting Equation

 from

 

the

National Institute for Occupational Safety and Health (NIOSH).

Website: www.cdc.gov/NIOSH.

1-6. EMF Information

Electric current flowing through any conductor causes localized electric

and magnetic fields (EMF). The current from arc welding (and allied pro-

cesses including spot welding, gouging, plasma arc cutting, and

induction heating operations) creates an EMF field around the welding

circuit.  EMF fields can interfere with some medical implants, e.g. pace-

makers. Protective measures for persons wearing medical implants

have to be taken. For example, restrict access for passers

by or con-

duct individual risk assessment for welders. All welders should use the

following procedures in order to minimize exposure to EMF fields from

the welding circuit:

1. Keep cables close together by twisting or taping them, or using a

cable cover.

2. Do not place your body between welding cables. Arrange cables

to one side and away from the operator.

3. Do not coil or drape cables around your body.

4. Keep head and trunk as far away from the equipment in the

welding circuit as possible.

5. Connect work clamp to workpiece as close to the weld as

possible.

6. Do not work next to, sit or lean on the welding power source.

7. Do not weld whilst carrying the welding power source or wire

feeder.

About Implanted Medical Devices:

Implanted Medical Device wearers should consult their doctor and the

device manufacturer before performing or going near arc welding,  spot

welding, gouging, plasma arc cutting, or induction heating operations.

If cleared by your doctor, then following the above procedures is recom-

mended.

Содержание MigMatic S400i

Страница 1: ...ion MIG GMAW Welding Flux Cored FCAW Welding Arc Welding Power Source OM 287504A 2020 05 MigMatic S400i S400iP S500i CE File MIG GMAW Wire Feeder For product information Owner s Manual translations an...

Страница 2: ...ducts Please take time to read the Safety Precautions They will help you protect yourself against potential hazards on the worksite We ve made installation and operation quick and easy With Miller you...

Страница 3: ...3 6 Environmental Specifications 9 3 7 Duty Cycle And Overheating 10 3 8 Volt Ampere Curves 11 SECTION 4 INSTALLATION 12 4 1 Selecting A Location 12 4 2 Selecting Cable Sizes 13 4 3 Weld Output Termi...

Страница 4: ......

Страница 5: ......

Страница 6: ...changed Occupational exposure is below the Exposure Limit Values ELVs YES NO for health effects at the standardized configurations if NO specific required minimum distances apply Occupational exposure...

Страница 7: ...n any of the follow ing electrically hazardous conditions are present in damp locations or while wearing wet clothing on metal structures such as floors gratings or scaffolds when in cramped positions...

Страница 8: ...If this is not possible tightly cover them with approved covers Do not weld where flying sparks can strike flammable material Protect yourself and others from flying sparks and hot metal Be alert that...

Страница 9: ...rks to move unit be sure forks are long enough to extend beyond opposite side of unit Keep equipment cables and cords away from moving vehicles when working from an aerial location Follow the guidelin...

Страница 10: ...te www global ihs com National Electrical Code NFPA Standard 70 from National Fire Protection Association Website www nfpa org and www sparky org Safe Handling of Compressed Gases in Cylinders CGA Pam...

Страница 11: ...tion Safe37 2017 04 Wear dry insulating gloves Do not touch electrode with bare hand Do not wear wet or damaged gloves Safe2 2017 04 Protect yourself from electric shock by insulating yourself from wo...

Страница 12: ...power requirements See rating label on unit and check input voltage available at site Safe34 2012 05 Become trained and read the instructions and labels before working on machine Safe35 2012 05 Wear...

Страница 13: ...2017 04 2 2 Miscellaneous Symbols And Definitions A Amperage V Volts Alternating Current AC Direct Current DC Remote On Off Protective Earth Ground Line Connection Three Phase Gas Metal Arc Welding G...

Страница 14: ...end user as necessary based upon application specific requirements The end user is solely responsible for selection and coordination of appropriate equipment adoption or adjustment of default weld par...

Страница 15: ...Electromagnetic Compatibility EMC This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low voltage supply system There can be p...

Страница 16: ...thermostat s opens output stops and cooling fan runs Wait fifteen minutes for unit to cool Reduce amperage or voltage or duty cycle before welding NOTICE Exceeding duty cycle can damage unit and void...

Страница 17: ...how the normal minimum and maximum voltage and amperage output capabilities of the welding power source Curves of other settings fall between the curves shown MIGMATIC S400i MIGMATIC S400iP MIGMATIC S...

Страница 18: ...2 Lifting Forks Use lifting eye or lifting forks to move unit If using lifting forks extend forks beyond opposite side of unit 3 Line Disconnect Device Locate unit near correct input power supply 4 1...

Страница 19: ...5 2x3 0 2x95 2x3 0 350 60 1 0 70 2 0 95 3 0 120 4 0 2x70 2x2 0 2x95 2x3 0 2x95 2x3 0 2x120 2x4 0 400 60 1 0 70 2 0 95 3 0 120 4 0 2x70 2x2 0 2x95 2x3 0 2x120 2x4 0 2x120 2x4 0 500 70 2 0 95 3 0 120 4...

Страница 20: ...rt from valve Close valve 3 Cylinder 4 Regulator Flowmeter Install so face is vertical 5 Regulator Flowmeter Gas Hose Connection 6 Welding Power Source Gas Hose Connection Connect supplied gas hose be...

Страница 21: ...ght hand BSP threads Obtain and install gas hose 4 Gas In Fitting 5 Gas Out Fitting The Gas In and Gas Out fittings have 1 4 right hand BSP male threads Obtain proper size type and length hose and mak...

Страница 22: ...56172374_6 A 2 3 1 4 7 7 Pin Receptacle Information 956172374_10 A REMOTE 7 PIN Socket Socket Information AWC CONTROL 1 Common 2 Automatic Water Cooler Control 3 Not Used 4 Automatic Water Cooler Prot...

Страница 23: ...See Section 4 10 Provides 42 volts AC to power wire feeder and signal communication to feeder 5 Cable Positive Connect to weld output terminal for MIG welding lo cated on the rear panel of the weldin...

Страница 24: ...remote control M 0 volts AC output remote control N 0 volts AC output remote control Communication G Chassis common A Data reception serial gate B Common communication serial gate C Data transmissions...

Страница 25: ...lding Power Source 3 Wire Feeder 4 Gas Cylinder 5 Gas Hose 6 Wire Feeder Cable See Section 4 9 7 Welding Gun Connect to welding torch connector in wire feeder 8 Work Lead Connect work lead to negative...

Страница 26: ...ve Supply Current I1eff A 23 2 23 2 27 2 Max Recommended Standard Fuse Rating In Amperes 1 Time Delay Fuses 2 Normal Operating Fuses 3 30 35 30 35 45 50 Maximum Recommended Supply Conductor Length In...

Страница 27: ...OM 287504 Page 21 4 13 Connecting 3 Phase Input Power input2 2012 05 Ref 803766 C Ref 956172374_9_A GND PE Earth Ground L1 2 1 L2 L3 3 3 4 5 6 7 Tools Needed...

Страница 28: ...Three Phase Operation 1 Input Power Cord 2 Disconnect Device switch shown in the OFF position 3 Green Or Green Yellow Grounding Conductor 4 Disconnect Device Grounding Terminal 5 Input Conductors L1 L...

Страница 29: ...icator Light LED illuminates when input power is on 6 High Temperature Light Light comes on if unit overheats Welding can resume when unit has cooled see Section 5 2 7 Gas Out 1 4 BSP Fitting 8 14 Pin...

Страница 30: ...ne by Factory Authorized Service Agent Every 3 Months Labels Replace Cracked Torch Body Repair Or Replace Cracked Cables Every 3 Months Cables And Cords Every 3 Months Clean And Tighten Weld Connectio...

Страница 31: ...see Section 4 13 No weld output Input voltage outside acceptable range of variation see Section 4 12 4 13 Check repair or replace remote control Unit overheated Allow unit to cool with fan on see Sect...

Страница 32: ...OM 287504 Page 26 SECTION 7 ELECTRICAL DIAGRAMS PC2 PC2 PC4 PC7 FM FM FM FM Figure 7 1 Circuit Diagram for Migmatic S400i...

Страница 33: ...OM 287504 Page 27 956172379 A PC5 PC5 HD1 HD2 PC1 PC8...

Страница 34: ...OM 287504 Page 28 PC2 PC2 PC4 PC7 FM FM FM FM Figure 7 2 Circuit Diagram for Migmatic S400iP...

Страница 35: ...OM 287504 Page 29 956172380 A PC5 PC5 PC1 PC8 HD2 HD1...

Страница 36: ...OM 287504 Page 30 PC4 PC7 PC2 PC2 FM FM FM FM Figure 7 3 Circuit Diagram for Migmatic S500i...

Страница 37: ...OM 287504 Page 31 956172381 A PC1 PC5 PC5 HD1 HD2 PC8...

Страница 38: ...tion Part No Item No Figure 8 1 Main Assembly MigMatic S400i 400iP 500i Quantity Dia Mkgs 1 056076323 Receptacle Twist Lock Power 2 2 156007048 Cover 65 x 27 1 3 116170004 Grid Front 2 4 056052017 Ins...

Страница 39: ...057084229 Circuit Board Driver 2 34 156005230 Support Heatsink 1 35 056082110 Heatsink 1 36 156005231 Support Circuit Board 4 37 156122104 Panel Right Side 1 38 156121052 Cover 1 39 PC7 057084230 Cir...

Страница 40: ...Notes Securely connect work clamp to a clean area close to the weld joint Welding Tip...

Страница 41: ...Notes...

Страница 42: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...

Страница 43: ...sma Cutting Torches No Labor Induction Heating Power Sources Coolers NOTE Digital Recorders are Warranted Separately by the Manufacturer Load Banks Motor Driven Guns except Spoolmate Spoolguns PAPR Bl...

Страница 44: ...Please complete and retain with your personal records Owner s Record Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Supplies and Consumable...

Отзывы: