OM-206 360 Page 9
2-6. Weld Output Terminals And Selecting Cable Sizes
Y
ARC WELDING can cause Electromagnetic Interference.
To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed
and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving
the welding machine, using shielded cables, using line filters, or shielding the work area.
Total Cable (Copper) Length In Weld Circuit Not Exceeding
100 ft (30 m) Or Less
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Welding
Amperes
10
−
60%
Duty
Cycle
60
−
100%
Duty Cycle
10
−
100% Duty Cycle
150
30
30
35
50
60
70
95
95
200
30
35
50
60
70
95
120
120
250
35
50
60
70
95
120
2 x 70
2 x 70
Turn Off power before
connecting to weld output
300
50
60
70
95
120
2 x 70
2 x 95
2 x 95
connecting to weld output
terminals.
350
60
70
95
120
2 x 70
2 x 95
2 x 95
2 x 120
400
60
70
95
120
2 x 70
2 x 95
2 x 120
2 x 120
500
70
95
120
2 x 70
2 x 95
2 x 120
3 x 95
3 x 95
600
95
120
2 x 70
2 x 95
2 x 120
3 x 95
3 x 120
3 x 95
700
120
2 x 70
2 x 95
2 x 120
3 x 95
3 x 120
3 x 120
4 x 120
800
120
2 x 70
2 x 95
2 x 120
3 x 120
3 x 120
4 x 120
4 x 120
Weld cable size = mm