A complete Parts List is available at www.MillerWelds.com
OM-257811 Page 11
SECTION 6 − MAINTENANCE & TROUBLESHOOTING
6-1. Routine Maintenance
!
Disconnect power
before maintaining.
n
= Check
Z
= Change
~
= Clean
Δ
= Repair
l
= Replace
* To be done by Factory Authorized Service Agent
Every
3
Months
~
Coolant Filter, durning heavy
service, clean more frequently.
~
Blow out heat exchanger fins.
n
Check coolant level. Top off with
distilled or deionized water if necessary.
Every
6
Months
nl
Hoses
nl
Labels
Z
Replace coolant.
6-2. Coolant Maintenance
805 502-A
!
Disconnect input power before maintain-
ing.
!
Dispose of used coolant according to na-
tional, state, and local codes. Do not pour
down drain.
NOTICE − Do not run cooler without coolant in tank.
1
Coolant Filter
Unscrew housing to clean filter (see Section 6-1).
Assemble and install cleaned coolant filter.
Changing Coolant
Changing coolant: Drain coolant by removing cap
and tipping unit forward, or use suction pump. Fill
with clean water and run for 10 minutes. Drain and
refill with coolant (see section 4-3). Install cap.
NOTICE − If replacing hoses, use hoses compati-
ble with ethylene glycol, such as Buna-n, Neo-
prene, or Hypalon. Oxy-acetylene hoses are not
compatible with any product containing ethylene
glycol.
1