background image

ORIGINAL INSTRUCTIONS − PRINTED IN USA

©

 2017 Miller Electric Mfg. Co. 

2017−01

Miller Electric Mfg. Co.

An Illinois Tool Works Company
1635 West Spencer Street
Appleton, WI 54914 USA

International Headquarters−USA
USA Phone: 920-735-4505 Auto-Attended
USA & Canada FAX: 920-735-4134
International FAX: 920-735-4125

For International Locations Visit

www.MillerWelds.com

Model Name

Serial/Style Number

Purchase Date

(Date which equipment was delivered to original customer.)

Distributor

Address

City

State

Zip

Please complete and retain with your personal records.

Always provide Model Name and Serial/Style Number.

Contact a DISTRIBUTOR or SERVICE AGENCY near you.

Welding Supplies and Consumables

Options and Accessories

Personal Safety Equipment

Service and Repair

Replacement Parts

Training (Schools, Videos, Books)

Technical Manuals (Servicing Information
and Parts)

Circuit Diagrams

Welding Process Handbooks

Contact the Delivering Carrier to:

For Service

Owner’s Record

File a claim for loss or damage during
shipment.

For assistance in filing or settling claims, contact
your distributor and/or equipment manufacturer’s
Transportation Department.

Contact your Distributor for:

 

To locate a Distributor or Service Agency visit
www.millerwelds.com or call 1-800-4-A-Miller

Содержание Coolmate 1.3

Страница 1: ...Coolmatet1 3 Processes Description TIG GTAW Welding OM 257811C 2017 02 File TIG GTAW MIG GMAW Welding For product information Owner s Manual translations and more visit www MillerWelds com...

Страница 2: ...ntinue the tradition They re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929 This Owner s Manual is designed to help you get...

Страница 3: ...sements 4 2 5 Principales normes de s curit 4 SECTION 3 DEFINITIONS 5 3 1 Additional Safety Symbols And Definitions 5 3 2 Miscellaneous Symbols And Definitions 6 SECTION 4 SPECIFICATIONS 7 4 1 Serial...

Страница 4: ......

Страница 5: ...can kill D Do not touch live electrical parts D Disconnect input power or stop engine before installing or servicing this equipment Lockout tagout input power according to OSHA 29 CFR 1910 147 see Sa...

Страница 6: ...Welding and Cutting American Welding Society Standard AWS F4 1 from Glob al Engineering Documents phone 1 877 413 5184 website www global ihs com Safe Practices for Welding and Cutting Containers tha...

Страница 7: ...ct d organes lectriques sous tension peut provoquer des accidents mortels ou des br lures graves Le circuit d alimentation et les circuits internes de la machine sont galement sous tension lorsque l a...

Страница 8: ...robl mes reproductifs Code de sant et de s curit de Californie chapitre 25249 5 et suivants Ce produit contient des produits chimiques notamment du plomb dont l tat de Californie reconna t qu ils prov...

Страница 9: ...recycle Waste Electrical and Electronic Equipment WEEE by disposing at a designated collection facility Contact your local recycling office or your local distributor for further information Safe37 201...

Страница 10: ...Definitions A Amperes V Volts Hz Hertz Water Coolant Input I1max Rated Maximum Supply Current Input Power Line Connection IP Degree Of Protection Power On Indica tor Single Phase Alternating Current...

Страница 11: ...Input Amperage 5 9 Amperes 4 3 Coolant Specifications Do not use conductive coolant Application Coolant GTAW Or Where High Frequency Current Is Used Low Conductivity Coolant 043810 Distilled Or Deion...

Страница 12: ...A 1 Dimensions A 11 25 in 286 mm B 10 375 in 264 mm C 24 in 610 mm D 15 4375 in 392 mm E 9 59 in 244 mm F 5 16 in Dia 4 Holes Weight 43 lb 20 kg 1 Mounting Bracket Optional Used to mount cooler to a...

Страница 13: ...In Hose Fittings have 5 8 18 left hand threads Connect hoses with proper fittings as shown Some power sources may require a TIG block 3 Coolant Tank Cap 4 115 Volt AC Grounded Receptacle A dedicated c...

Страница 14: ...Connect hoses as shown 1 Coolant Out Hose 2 Coolant In Hose Fittings have 5 8 18 left hand threads Connect hoses with proper fittings as shown 3 Coolant Tank Cap 4 115 Volt AC Grounded Receptacle A de...

Страница 15: ...ance 805 502 A Disconnect input power before maintain ing Dispose of used coolant according to na tional state and local codes Do not pour down drain NOTICE Do not run cooler without coolant in tank 1...

Страница 16: ...g when motor has cooled Have Factory Authorized Service Agent check Power switch S1 and motor Mot Decreased or no coolant flow Add coolant Check for clogged hoses or coolant filter Clean filter or cle...

Страница 17: ...Notes...

Страница 18: ...TM 216 869 Page 14 Dynasty 350 700 Maxstar 350 700 Notes...

Страница 19: ...Guns Subarc SAW Torches and External Cladding Heads Remote Controls and RFCS RJ45 Replacement Parts No labor Spoolmate Spoolguns Miller s True Blue Limited Warranty shall not apply to 1 Consumable co...

Страница 20: ...your personal records Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Supplies and Consumables Options and Accessories Personal Safety Equip...

Отзывы: