Complete Parts List is available at www.MillerWelds.com
OM-258413 Page 26
5-6.
Selecting Cable Sizes*
NOTICE − The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source
is 100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine
cable size.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
100 ft (30 m) or Less
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Welding
Amperes
10 − 60%
Duty
Cycle
AWG (mm
2
)
60 − 100%
Duty Cycle
AWG (mm
2
)
10 − 100% Duty Cycle
AWG (mm
2
)
100
4 (20)
4 (20)
4 (20)
3 (30)
2 (35)
1 (50)
1/0 (60)
1/0 (60)
150
3 (30)
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
3/0 (95)
200
3 (30)
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
4/0 (120)
250
2 (35)
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x2/0 (2x70)
300
1 (50)
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x3/0 (2x95)
350
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x3/0 (2x95)
2x4/0 (2x120)
400
1/0 (60)
2/0 (70)
3/0 (95)
4/0 (120)
2x2/0 (2x70)
2x3/0 (2x95)
2x4/0 (2x120)
2x4/0 (2x120)
*
This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
( ) = mm
2
for metric use
***For distances longer than those shown in this guide, see AWS Fact Sheet No. 39, Welding Cables, available from the American Welding
Society at http://www.aws.org.
Ref. S-0007-M 2017−08
!
Stop engine.
!
Failure to properly connect
weld cables may cause exces-
sive heat and start a fire, or
damage your machine.
!
Turn off power before connect-
ing to weld output terminals.
!
Do not use worn, damaged,
undersized, or repaired cables.
1
Work Weld Output Terminal
2
Electrode Weld Output Terminal
Connect work cable to Work terminal.
Connect electrode holder cable or
electrode weld cable to Electrode ter-
minal for Stick and MIG welding.
Connect torch cable to Electrode ter-
minal for TIG welding.
Use Process Selector switch to
select type of weld output (see
Section 6-2).
.
See Sections 6-3 thru 6-5 for typi-
cal process connections and
control settings.
5-7.
Weld Output Terminals
259 707 / 258 070-A
1
2
Содержание Bobcat 250 Diesel
Страница 20: ...Complete Parts List is available at www MillerWelds com OM 258413 Page 16 Notes...
Страница 37: ...Complete Parts List is available at www MillerWelds com OM 258413 Page 33 6 6 Fuel Hour Gauge Descriptions...
Страница 52: ...OM 258413 Page 48 SECTION 10 ELECTRICAL DIAGRAMS 258 418 B Figure 10 1 Circuit Diagram For Welder Generator...
Страница 53: ...OM 258413 Page 49 Notes...
Страница 76: ...Notes...
Страница 77: ...Notes...
Страница 78: ...Notes...