background image

Complete Parts List is available at www.MillerWelds.com

OM-266621 Page 31

6-5. Front Panel CST Controls

A. Overview

Ref. 217 192-B / 803 942-A

Green on nameplate indicates a TIG
function and Gray indicates a Stick

function.

1

Power Switch

Use switch to turn unit and indicator light

On/Off.

2

Output Indicator Light

When unit is first energized this indicator

light flashes several times and then

illuminates continuously. When unit is shut

down, the indicator light flashes several

times and the cooling fan will run briefly,

then both will turn off completely.
3

Process Control

See Section B.

4

Amperage Control

See Section C.
5

High Temperature Shutdown Light

When unit is first energized this indicator

light illuminates for approximately 1 second

to provide visual confirmation that the light

is functioning properly (see Section 8-12).
6

Remote 14 Receptacle

See CST Owner’s Manual OM-217655.

6

5

1

4

3

2

Содержание Big Blue 450 Duo CST

Страница 1: ...017 10 Big Blue 450 Duo CST Processes Description TIG GTAW Welding Stick SMAW Welding Engine Driven Welder Generator File Engine Drive For product information Owner s Manual translations and more visi...

Страница 2: ...ntinue the tradition They re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929 This Owner s Manual is designed to help you get...

Страница 3: ...SPECIFICATIONS 17 4 1 Serial Number And Rating Label Locations 17 4 2 Weld Power And Engine Specifications 17 4 3 Dimensions Weights And Operating Angles 17 4 4 Environmental Specifications 18 4 5 Tie...

Страница 4: ...gine Cooling System 39 8 9 Adjusting Engine Speed 39 8 10 Servicing Fuel And Lubrication Systems 40 8 11 Overload Protection 41 8 12 Troubleshooting CST 42 8 13 Troubleshooting Generator 43 SECTION 9...

Страница 5: ...gh risk of unavoid able or accidental contact with the workpiece or ground For these conditions use the following equipment in order presented 1 a semiautomaticDC constant voltage wire welder 2 a DC m...

Страница 6: ...g sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Watch for fire and keep a fire extinguisher nearby Be aware that welding on a ceiling floor bu...

Страница 7: ...hot parts use proper tools and or wear heavy insu lated welding gloves and clothing to prevent burns STEAM AND HOT COOLANT can burn If possible check coolant level when engine is cold to avoid scaldi...

Страница 8: ...can burn Do not touch hot compressor or air system parts Allow cooling period before working on equipment To handle hot parts use proper tools and or wear heavy insu lated welding gloves and clothing...

Страница 9: ...any metal when threading welding wire OVERUSE can cause OVERHEATING Allow cooling period follow rated duty cycle Reduce current or reduce duty cycle before starting to weld again Do not block or filte...

Страница 10: ...e Practice For Occupational And Educational Eye And Face Protec tion ANSI Standard Z87 1 from American National Standards Institute 25 West 43rd Street New York NY 10036 phone 212 642 4900 web site ww...

Страница 11: ...appareil en est quip Des pr cautions de s curit suppl mentaires sont requises dans des environnements risque comme les endroits humides ou lorsque l on porte des v tements mouill s sur des structures...

Страница 12: ...essures ou m me la mort Fermer l alimentation du gaz comprim en cas de non utilisation Veiller toujours bien a rer les espaces confin s ou se servir d un respirateur d adduction d air homologu LES RAY...

Страница 13: ...ication sp cifique les maintenir ainsi que les l ments associ s en bon tat Tourner le dos la sortie de vanne lors de l ouverture de la vanne de la bouteille Ne pas se tenir devant ou derri re le r gul...

Страница 14: ...ppement 2 4 Dangers li s l air comprim Un QUIPEMENT PNEUMATIQUE risque de provoquer des blessures ou m me la mort Une installation ou une utilisation incorrecte de cet appareil pourrait conduire des d...

Страница 15: ...tretien de l appareil Lire les informations de s curit au d but du manuel et dans chaque section N utiliser que les pi ces de rechange recommand es par le constructeur Effectuer l installation l entre...

Страница 16: ...canique en enga geant le fil de soudage L EMPLOI EXCESSIF peut SURCHAUFFER L QUIPEMENT Laisser l quipement refroidir respecter le fac teur de marche nominal R duire le courant ou le facteur de marche...

Страница 17: ...auga Ontario Canada L4W 5NS phone 800 463 6727 website www csagroup org Safe Practice For Occupational And Educational Eye And Face Protec tion ANSI Standard Z87 1 from American National Standards Ins...

Страница 18: ...OM 266621 Page 14...

Страница 19: ...rs of operation keep welding load above 200 amperes Do not weld below 200 amperes of output 50 h std Safe55 2012 05 After the first 50 hours of operation change the engine oil and filter Never use gen...

Страница 20: ...An Environment With Increased Risk Of Electric Shock Engine Driven Three Phase Alternator With Rectifier Three Phase Single Phase Direct Current DC Alternating Current Circuit Protection Protective Ea...

Страница 21: ...ontinuous 120 240 V AC 60 Hz Three Phase 12 kVA kW 240 V AC 60 Hz 71 dB 96 Lwa at 23 ft 7 m Full Load T4F Mitsubishi S4L2 Water Cooled Four Cylinder Diesel Engine 24 7 HP Domestic Models T4F 11 5 gal...

Страница 22: ...els Performance Curves 0 100 200 300 400 500 0 10 20 30 40 50 60 70 80 90 100 DUTY CYCLE WELD AMPHERES A Duty Cycle 266 503 A 1 100 Duty Cycle Duty Cycle is percentage of 10 minutes that unit can weld...

Страница 23: ...urves of all other settings fall between the curves shown XX10 Stick Mode XX18 Stick Mode 0 20 40 60 80 100 0 100 200 300 400 500 600 DC VOLTS DC AMPERES EXX10 SOFT MIN EXX10 STIFF MIN EXX10 SOFT MAX...

Страница 24: ...output capabilities of the welding generator Curves of all other settings fall between the curves shown 0 10 20 30 40 50 60 70 80 0 50 100 150 200 250 300 350 DC Volts DC Amperes Max 150 Amps Min E AC...

Страница 25: ...ehicle or trailer and comply with all DOT and other applicable codes Do not weld on base Welding on base can cause fuel tank fire or ex plosion Weld only on the four mounting brackets or bolt unit dow...

Страница 26: ...ing auxiliary equipment If unit does not have GFCI receptacles use GFCI protected extension cord Do not use GFCI receptacles to power life support equipment 1 Equipment Grounding Terminal On Front Pan...

Страница 27: ...On Always disconnect the negative battery cable before charging battery 5 4 Connecting The Battery 1 2 in Tools Needed Conn_Batt2 2014 11 S 0756 C 161 002 Shown with door open and rocker panel remove...

Страница 28: ...Full levels If recovery tank coolant level was low also check coolant level in radiator Add coolant if level is below bottom of radia tor filler neck Unit is shipped with an engine coolant mix ture o...

Страница 29: ...x2 0 2x70 2x2 0 2x70 300 1 50 1 0 60 2 0 70 3 0 95 4 0 120 2x2 0 2x70 2x3 0 2x95 2x3 0 2x95 350 1 0 60 2 0 70 3 0 95 4 0 120 2x2 0 2x70 2x3 0 2x95 2x3 0 2x95 2x4 0 2x120 400 1 0 60 2 0 70 3 0 95 4 0 1...

Страница 30: ...ure connecting hardware is adequate for expected amperage and that the junction is properly insulated NOTICE When using these connections as a common work terminal all connections must be of the same...

Страница 31: ...the junction is properly insulated NOTICE When using these connections as a common work terminal all connections must be of the same polarity NOTICE For common work connection work cable must be able...

Страница 32: ...s Below 325 F 05 C turn engine control switch to Run position Push Preheat switch up for 30 seconds Turn Engine Control switch to Start Release Engine Control switch and Preheat switch when engine sta...

Страница 33: ...To turn on heater connect heater plug to 120 volts AC receptacle Do not run engine while en gine block heater is on NOTICE In extremely cold weath er heater should be connected to power source when en...

Страница 34: ...Complete Parts List is available at www MillerWelds com OM 266621 Page 30 6 4 Fuel Hour Gauge Descriptions...

Страница 35: ...icator light flashes several times and then illuminatescontinuously When unit is shut down the indicator light flashes several times and the cooling fan will run briefly then both will turn off comple...

Страница 36: ...gher dig arc force that gives a slightly more fluid weld puddle more arc snap and reduces the potential for electrode sticking at shorter arc lengths Stick E XX10 Soft This setting provides lower dig...

Страница 37: ...g procedures RC11 supplies 60 Hz single phase power at weld power speed Maximum continuousoutput from RC11 is 10 kVA kW 3 SupplementaryProtectors CB4 CB5 4 Supplementary Protector CB6 CB4 and CB5 prot...

Страница 38: ...lated to ground faults Reset and test GFCI receptacle according to the following procedures A solid green LED indicates power to the GFCI A solid red LED indicates that the GFCI has been tripped Reset...

Страница 39: ...ECTION 8 MAINTENANCE TROUBLESHOOTING 8 1 Maintenance Label Mitsubishi Engine North America 1250 Greenbriar Dr Suite E Addison IL 60101 630 268 0750 Http www mitsubishi engine com Use web site to locat...

Страница 40: ...ours Section 8 4 Battery Terminals Air Cleaner Hoses Air Cleaner Element Unreadable Labels Every 500 Hours 1 2 in 13 mm NOTICE Change engine oil and filter after initial 50 to 75 hours of use Engine M...

Страница 41: ...ement three times 1 Intake Manifold 2 Service Indicator Optional Customer Supplied 3 Service Indicator Window 4 Service Indicator Reset Button Service air cleaner element if red band appears in window...

Страница 42: ...Mark and disconnect leads at brush hold er assembly Remove assembly Press on brush to be sure springs compress Replace assembly if brushes are dam aged or if brush material is at or near mini mum leng...

Страница 43: ...d coolant to recov ery tank until coolant level is between Cold Full and Hot Full levels If recovery tank coolant level was low also check coolant level in radiator Add coolant if level is below botto...

Страница 44: ...on new fil ter Install new filter and reinstall re taining ring Inspect fuel lines and replace if cracked or worn To drain water from fuel system See engine manual To replace secondary in line fuel f...

Страница 45: ...acing front panel 4 Fuse F1 F1 protects the stator exciter winding from overload If F1 opens weld and generator power is low or stops entirely 5 Supplementary Protector CB2 6 Supplementary Protector C...

Страница 46: ...rts or opens in wir ing Failed boost inductor Have Factory Authorized Service Agent replace boost inductor if necessary Failed LEM Have Factory Authorized Service Agent replace LEM if necessary Open c...

Страница 47: ...ring for opens Open secondary thermistor Have Factory Authorized Service Agent check thermistor on output heatsink and associated wiring for opens Shorted secondary thermistor Have Factory Authorized...

Страница 48: ...uel information Use correct grade oil for cold weather see Section 8 1 Have Factory Authorized Service Agent check Preheat switch S4 control relay CR3 and the glow plug Engine suddenly stops Check oil...

Страница 49: ...2 Filter Kit Mitsubishi S4l2 Includes 1 252781 Filter Fuel Spin on 1 213858 Filter Fuel In line 5 16x5 16 Mic 125 175 1 242882 Filter Lube Oil 1 197676 Element Air Cleaner 1 197679 Element Air Cleaner...

Страница 50: ...OM 266621 Page 46 SECTION 10 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For Welding Generator...

Страница 51: ...OM 266621 Page 47 247 963 D...

Страница 52: ...ge and current during run in period to properly seat piston rings and prevent wetstacking See name plate rating label or specifications section in this manual to find rated voltage and current NOTICE...

Страница 53: ...n if not provided on generator Start engine and run for several minutes For Load Bank Set load bank switches and then adjust generator A V control so load equals rated voltage and current of generator...

Страница 54: ...alth Fact Sheet No 29 Grounding of Portable And Vehicle Mounted Welding Gen erators 1 Equipment Grounding Terminal On Front Panel 2 Grounding Cable Not Supplied 3 Metal Vehicle Frame Connect cable fro...

Страница 55: ...e load and requires a constant amount of power 2 Non Resistive Load Equipment with a motor is a non re sistive load and requires approximatelysix times more power while starting the motor than when ru...

Страница 56: ...e Equipment Rating Starting Watts Running Watts Stock Tank De Icer 1000 1000 Grain Cleaner 1 4 HP 1650 650 Portable Conveyor 1 2 HP 3400 1000 Grain Elevator 3 4 HP 4400 1400 Milk Cooler 2900 1100 Milk...

Страница 57: ...00 1 HP 6000 1500 1 1 2 HP 8200 2200 2 HP 10 500 2800 Electric Chain Saw 1 1 2 HP 12 in 1100 1100 2 HP 14 in 1100 1100 Electric Trimmer Standard 9 in 350 350 Heavy Duty 12 in 500 500 Electric Cultivat...

Страница 58: ...must be at least twice the motor s running amperage kVA HP x HP x 1000 Volts Starting Amperage Example Calculate starting amper age required for a 230 V 1 4 HP mo tor with a motor start code of M Volt...

Страница 59: ...back to electric utility when service is re stored Install correct switch customer supplied Switch rating must be same as or greater than the branch overcurrent protection 3 Fused Disconnect Switch I...

Страница 60: ...0 15 40 4800 112 34 62 19 37 11 45 5400 100 30 62 19 50 6000 87 26 50 15 Conductor size is based on maximum 2 voltage drop Cord Lengths for 240 Volt Loads Use GFCI protection when operating auxiliary...

Страница 61: ...Notes...

Страница 62: ...Notes...

Страница 63: ...Guns Subarc SAW Torches and External Cladding Heads Remote Controls and RFCS RJ45 Replacement Parts No labor Spoolmate Spoolguns Miller s True Blue Limited Warranty shall not apply to 1 Consumable co...

Страница 64: ...your personal records Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Supplies and Consumables Options and Accessories Personal Safety Equip...

Отзывы: