OM-480 Page 16
ether1 12/96 – 153 382-A / Ref. 206 029
Stop engine.
Improper handling or expo-
sure to ether can harm your
health. Follow manufactur-
er’s safety instructions on
cylinder.
Do not use Ether Starting Aid
while engine is running.
Open side door(s).
1
Ether Cylinder
2
Nozzle
Remove cover and clean cylinder
nozzle.
3
Clamp
4
Fitting
5
Cap
6
Valve
Remove cap and clean fitting.
Install cylinder on fitting. Tighten
clamp.
After installing cylinder, wait at
least 10 minutes before using
to let ether particles settle and
prevent atomizer plugging.
Put cap on fitting when cylinder is
removed.
1
2
3
4
6
5
4-5.
Installing Ether Cylinder (Optional Ether Starting Aid)
Ref. 800 162-A
Open left side door.
1
Bracket
Route cables through bracket.
2
Positive (+) Weld Output
Terminal
3
Negative (–) Weld Output Ter-
minal
For Stick welding Direct Current
Electrode Positive (DCEP), con-
nect work cable to (–) terminal and
electrode holder cable to (+)
terminal.
For Direct Current Electrode Nega-
tive (DCEN), reverse cable
connections.
If equipped with optional polarity
switch, connect electrode holder
cable to Electrode (–) terminal and
work cable to Work (+) terminal.
For FCAW welding, connect work
cable to (–) terminal and wire feeder
cable to (+) terminal.
Close door.
Tools Needed:
4-6.
Connecting To Weld Output Terminals
3/4 in
1
2
3
Содержание Big Blue 251D
Страница 4: ......
Страница 36: ...OM 480 Page 32 SECTION 8 ELECTRICAL DIAGRAM SC 190 650 B Figure 8 1 Circuit Diagram For Welding Generator ...
Страница 47: ...OM 480 Page 43 Notes ...
Страница 57: ......
Страница 58: ......