OM-480 Page 14
SECTION 4 – INSTALLATION
4-1.
Installing Welding Generator
install1 7/02 – Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854
Electrically bond generator frame to
vehicle frame by metal-to-metal
contact.
GND/PE
1
2
Always securely fasten welding
generator onto transport vehicle
or trailer and comply with all DOT
and other applicable codes.
Always ground generator frame to
vehicle frame to prevent electric
shock and static electricity haz-
ards.
If unit does not have GFCI recep-
tacles, use GFCI-protected exten-
sion cord.
1
Equipment Grounding Terminal (On
Front Panel)
2
Grounding Cable (Not Supplied)
3
Metal Vehicle Frame
Connect cable from equipment ground
terminal to metal vehicle frame. Use #10
AWG or larger insulated copper wire.
3
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
OR
Movement
Airflow Clearance
Location
Grounding
OR
Do Not Lift Unit From End
4-2.
Connecting The Battery
156 011-A / Ref. 206 029 / S-0756
1/2 in
+
–
Connect Negative (–)
Cable Last.
Tools Needed: